thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE
AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
1.1.
ELECTRICAL SAFETY
 WARNING! It is the responsibility of the owner and the operator
to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they
are safe. You must inspect power cables, plugs, sockets and any
other connectors for wear or damage. You must ensure that the risk
of electric shock is minimised by the installation of appropriate safety
devices. A residual current circuit Breaker (rccB) should be
incorporated in the main distribution board. We also recommend that
a residual current device (rcd) is used. It is particularly important
to use an rcd with portable products that are plugged into a supply
which is not protected by an rccB. If in any doubt consult a
qualified electrician. You may obtain a residual current device by
contacting your sealey dealer. You must also read and understand
the following instructions concerning electrical safety.
1.1.1. the Electricity at Work Act 1989 requires that all portable
electrical appliances, if used on business premises, are tested
by a qualified electrician, using a Portable Appliance tester
(PAt), at least once a year.
1.1.2. the Health & Safety at Work Act 1974 makes owners of
electrical appliances responsible for the safe condition of
those appliances and the safety of the appliance operators. If
in any doubt about electrical safety, contact a qualified
electrician.
1.1.3. ensure that the insulation on all cables and on the appliance
is safe before connecting it to the power supply. see 1.1.1.
and 1.1.2. and use a Portable Appliance tester.
1.1.4. ensure that cables are always protected against short circuit
and overload.
1.1.5. regularly inspect power supply cables and plugs for wear or
damage and check all connections to ensure that none is loose.
1.1.6. Important: ensure that the voltage marked on the appliance
matches the power supply to be used and that the plug is
fitted with the correct fuse - see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors.
Immediately have any faulty item repaired or replaced by a
qualified electrician. When a Bs 1363/A uK 3 pin plug is
damaged, cut the cable just above the plug and dispose of
the plug safely.
fit a new plug according to the following instructions (uK only).
a) Connect the GREEN/YELLOW earth wire to the earth
terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all
wires have been correctly connected, that the cable outer
insulation extends beyond the cable restraint and that the
restraint is tight.
double insulated
products, which are
always marked with this
symbol
, are fitted
with live (brown) and
neutral (blue) wires only.
to rewire, connect the
wires as indicated to the
right. DO NOT connect
either wire to the earth
terminal.
Yellow & Green
Earth Wire
Brown
Live
Wire
Blue
Neutral
Wire
Cable
Restraint
FUSE RATING 13AMP
Original Language Version
InstructIons for:
EXHAUST FUME EXTRACTOR
WITH 6mtr HOSE
EFS/93.V4
Model no:
1.1.10. Products which require more than 13 amps are supplied
without a plug. In this case you must contact a qualified
electrician to ensure that a suitably rated supply is available.
We recommend that you discuss the installation of an
industrial round pin plug and socket with your electrician.
1.1.11. If an extension reel is used it should be fully unwound before
connection. A reel with an rcd fitted is preferred since any
appliance plugged into it will be protected. the cable core
section is important and should be at least 1.5mm², but to be
absolutely sure that the capacity of the reel is suitable for this
product and for others which may be used in the other output
sockets, we recommend the use of 2.5mm² section cable.
1.2
GENERAL SAFETY
WARNING! Ensure Health & Safety, local authority, and
general workshop practice regulations are adhered to when
using this equipment.
familiarise yourself with the application, limitations and
potential hazards of the extractor.
WARNING! Disconnect the unit from the mains power
before servicing or performing any maintenance.
Maintain the extractor in good condition (use an authorised
service agent).
replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the
warranty.
locate the extractor in a suitable working area, keep area clean
and tidy and free from unrelated materials. ensure there is
adequate lighting.
WARNING! Use only on level ground or slopes not exceeding 8º .
ensure there are no flammable or combustible materials near
the work area.
Keep children and unauthorised persons away from the working area.
DO NOT use the extractor for a task it was not designed to
perform.
DO NOT operate the extractor if any parts are damaged or
missing as this may cause failure or possible personal injury.
DO NOT get the extractor wet or use in damp or wet locations
or areas where there is condensation.
DO NOT allow untrained persons to operate the extractor.
DO NOT operate the extractor when you are tired or under the
influence of alcohol, drugs or intoxicating medication.
DO NOT use the extractor where there are flammable liquids,
solids or gases such as paint solvents, etc.
DO NOT leave the extractor operating unattended.
When not in use switch the extractor off and remove plug
from the power supply.
2. INTRODUCTION & SPECIFICATION
suitable for both large and small garages and workshops. excellent
as a back-up machine for garages with purpose-built fume extraction
units. complies with the latest eMc regulations and is powerful yet
quiet. suitable for small cars and commercials up to 10tonne GVW.
fitted with a exhaust pipe cone that includes a port to allow use with
gas analyser probes. supplied with 6mtr flexible ducting.
Specification:
Motor ........................................................................ 230V - 1ph 550W
Air flow ................................................................................560mtr³/hr
extraction height ............................................................ 120 to 750mm
Hose .............................................................................................. 6mtr
Weight ........................................................................................46.2kg
efs93.V4
Issue no.1
23/03/10

Advertisement

loading

Summary of Contents for Sealey EFS/93.V4

  • Page 1 EFS/93.V4 Model no: thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
  • Page 2 WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode. Sole UK Distributor, Sealey Group, www.sealey.co.uk...