Wips-200 series wireless process solution frequency hopping spread spectrum radio two-way (multipoint-to-point) for monitoring and control with expandable i/o options (36 pages)
Summary of Contents for Siemens SIMATIC IOT2000 SG-Shield
Page 1
Getting Started Introduction Safety instructions Weighing systems Installing/mounting IIOT weighing solutions SIMATIC IOT2000 SG-Shield Connecting Parameter assignment Operating Instructions Service and maintenance Diagnostics and troubleshooting Technical data Dimension drawings Ordering data Product documentation and support 7MH4647-0KK00-0AA2 08/2021 A5E50985404-AA...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Table of contents Getting Started ............................5 Commissioning the SIMATIC IOT2000 SG-Shield ..............5 Introduction ............................7 Purpose of this documentation .................... 7 Document history ........................ 7 Designated use ........................7 Checking the scope of delivery ..................... 7 Scope of delivery ......................... 8 Information on industrial use ....................
Page 4
Meaning of the device status ..................... 27 Technical data............................29 Dimension drawings ..........................31 Ordering data ............................33 11.1 Accessories ........................33 Product documentation and support ....................35 Product documentation ..................... 35 Technical support....................... 35 Index ..............................37 SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Read the entire device manual in order to achieve the optimum performance of the device. Procedure 1. Install the SIMATIC IOT2000 SG-Shield into the SIMATIC IOT2050. Installing the SIMATIC IOT2000 SG-Shield (Page 13) 2. Connect the load cells to the SIMATIC IOT2000 SG-Shield.
Page 6
Getting Started 1.1 Commissioning the SIMATIC IOT2000 SG-Shield SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
2. Report any claims for damages immediately to the shipping company. 3. Retain the damaged parts until clarification. 4. Check the consignment by comparing your order with the shipping documents for correctness and completeness. SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer...
The content reflects the technical status at the time of publishing. Siemens reserves the right to make technical changes in the course of further development.
Observe the information and symbols on the device. Do not remove any information or symbols from the device. Always keep the information and symbols in a completely legible state. SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Risk to personnel, system and environment can result from modifications to the device, particularly in hazardous areas. • Only carry out modifications that are described in the instructions for the device. Failure to observe this requirement cancels the manufacturer's warranty and the product approvals. SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Installing/mounting Installing the SIMATIC IOT2000 SG-Shield Requirement • The device is disconnected from the power supply. Procedure 1. Loosen the cover. Carefully press the blade of a flat screwdriver into the marked cutouts and carefully pull on the bottom shield cover.
Page 14
4.1 Installing the SIMATIC IOT2000 SG-Shield 5. Notice! Do not bend contact pins. Insert the contact pins of the SIMATIC IOT2000 SG-Shield so that they fit perfectly into the socket contacts of the main circuit board. 6. Fasten the cover.
• Disconnect the device from the power supply in good time when a thunderstorm is approaching. • Do not touch mains cables and data transmission cables during a thunderstorm. • Keep a sufficient distance from electric cables, distributors, systems, etc. SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Connecting 5.2 Connecting the SIMATIC IOT2000 SG-Shield Connecting the SIMATIC IOT2000 SG-Shield Procedure SENSE- EXC- SIGNAL- SENSE+ EXC+ SIGNAL+ ① SIMATIC IOT2000 SG-Shield ② Load cell ③ Load cell terminals ④ LEDs (Page 27) ① ② 1. Connect the SIMATIC IOT2000 SG-Shield to the four load cells For 4-wire load cells, do not connect SENSE - and SENSE+.
2. Right-click the used LAN network adapter and select "Properties" in the shortcut menu. 3. Select "Internet protocol Version 4 (TCP/IPv4)". 4. Click the "Properties" button. Figure 6-1 Windows: "Local Area Connection" window SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
6. Install the following Node-Red libraries: – node-red-dashboard – node-red-contrib-modbus – node-red-contrib-bit – @mindconnect/node-red-contrib-mindconnect – node-red-contrib-config 7. Download the Node-Red example program for SIMATIC IOT2000 SG-Shield (https:// support.industry.siemens.com/cs/ww/de/ps/17781/dl). 8. Import the Node-Red example program for SIMATIC IOT2000 SG-Shield. 9. Click "Deploy". Calibrate scale with Node-Red...
Bit 1: Load cell input faulty Bit 2: Checksum error Bit 3: Checksum error (data) Bit 4: Watchdog error Bit 5: ADC error Bit 6: Temperature warning Bit 7: Firmware update error Temperature float -50.0 +150. 2051 SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Page 22
Bit 6: Power supply failure Excitation Voltage (V) float 0.000000 0.000000 9.99999 2024 Impedance Value (Ohm) float 0.000000 0.000000 10000.0 2026 Sense Voltage (V) float 0.000000 0.000000 9.99999 2034 EXC-Current (mA) float 0.000000 0.000000 199.999 2042 SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
(n = max. 250) weights which are recorded by the weighing module every 10 ms, e.g. when n = 10, the mean of 10 weights is calculated. Every 10 ms, the oldest value is discarded and the newest value included in the calculation. SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Characteristic value = 2.018 mV/V 6.10 MODBUS RTU response delay (only for SG-Shield OEM) This parameter defines the delay of a response to a data request by the MODBUS RTU master (in ms). SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Information on battery/product return (WEEE) (https:// support.industry.siemens.com/cs/document/109479891/) Note Special disposal required The device includes components that require special disposal. • Dispose of the device properly and environmentally through a local waste disposal contractor. SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Page 26
Service and maintenance 7.1 Disposal SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Check the permissible ambient temperature in the section: Technical data (Page 29). Bit 7 Firmware update error It was not possible to update the firmware. Try again. • Contact SIWAREX Support if the error occurs multiple times. SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Page 28
Diagnostics and troubleshooting 8.2 Meaning of the device status SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Technical data Because you insert the SIMATIC IOT2000 SG-Shield into the SIMATIC IOT2050, the same technical specifications apply as for SIMATIC IOT2050: • Type of protection: IP20 in accordance with IEC 60529; • Electromagnetic compatibility; • Ambient conditions All technical specifications can be found in the SIMATIC IOT2050 Operating Instructions (https:// support.industry.siemens.com/cs/de/en/view/109779016) in the section "Technical...
Ordering data 11.1 Accessories You can order accessories online: Industry Mall (https://mallstage.industry.siemens.com/ mall/en/b0/Catalog/Products/10038765?tree=CatalogTree) SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Additional information on our technical support can be found at Technical Support (http:// www.siemens.com/automation/csi/service). Service & support on the Internet In addition to our technical support, Siemens offers comprehensive online services at Service & Support (http://www.siemens.com/automation/serviceandsupport). SIMATIC IOT2000 SG-Shield Operating Instructions, 08/2021, A5E50985404-AA...
Page 36
Product documentation and support A.2 Technical support Contact If you have further questions about the device, contact your local Siemens representative at Personal Contact (http://www.automation.siemens.com/partner). To find the contact for your product, go to "all products and branches" and select "Products &...