Technical specifications

Table 4- 1
Technical specifications of the transponder RTLS4060T
Product name
PULSE radio frequencies (localization)
Wireless method
Transmission speed
Operating frequency rated value
Bandwidth
Frequency range
Transmit power
Range
Accuracy of the localization (typical)
Antennas
PHASE radio frequencies (communication and optional localization)
Wireless method
Transmission speed
Operating frequency rated value
Bandwidth
Frequency range
Transmit power
Range
Accuracy of the localization (typical)
Antennas
Digital inputs
Input voltage
Input impedance
Digital outputs
Output
Output current
Output voltage
Load
SIMATIC RTLS4060T
Operating Instructions, 01/2021, C79000-G8976-C550-03
SIMATIC RTLS4060T
IEEE 802.15.4-2015 UWB HRP PHY
850 kbit/s
3993.6 MHz (UWB channel 2; CE, FCC)
6489.6 MHz (UWB channel 5; CE, FCC, ISED)
499.2 MHz
3100 MHz ... 4800 MHz (CE, FCC)
6000 MHz ... 7000 MHz (CE, FCC, ISED)
0.037 mW (-41.3 dBm/MHz)
Maximum 30 m
0.2 m
Built-in UWB antenna
IEEE 802.15.4
1 Mbit/s
2405 MHz ... 2480 MHz
2 MHz; data transmission on 802.15.4; channels configura-
ble
2400 MHz ... 2482 MHz
Maximum 12.6 mW (configurable)
Maximum 500 m
1 m
Built-in 2.4 GHz antenna
DC 0 ... 24 V
4,7 kOhm
High-side switch
Maximum 250 mA, short-circuit proof
0 V or supply voltage
Any
6GT2700-6DE03, 6GT2700-6DE13
6GT2700-6DE33
4
15