Camera Setting
<Control Board>
1. ID Setting
1
·
99
Default ID 1 and can be set ID 1 to 99 at S2,(default) protocol.
Refer to the Figure6 protocol selection table
2. Protocol and Baud rate Setting
Baud rate
2400
4800
9600
Set
Set off
Set on
SW3-1 off sets Pelco-D and S2 protocol automatically.
SW3-1 on is for test switch for pelco-D protocol of camera module.
Please DO NOT change protocol, Baud rate and ID setting data of the Zoom module
inside. Refer t o the 24 page for detail.
Sw2
Sw1
Figure5. Lottery and Dip Switches
SW2
SW1
0
1
·
·
9
9
SW3-2
SW3-3
OFF
ON
ON
OFF
OFF
OFF
SW3-1
OFF
ON
Figure6. Baud rate and Protocol selection tables.
Sw3
- 8 -