Overview
40G-4X10G-CU-A, 7M, 10M
40G-AOC, 1M, 2M, 3M, 5M, 7M, 10M, 15M
Hardware Specifications
The following table contains hardware specifications for the Firepower 4100.
Table 11: Firepower 4100 Hardware Specifications
Specification
Physical
Form factor
Rack mount
Dimensions (H x W
x D)
Weight
Storage
SSD
MSP
Memory
DDR4 DIMM
4110
4120
1 RU
Fits standard 19-inch (48.3-cm) square-hole rack
Mount rails included
4-post EIA-310-D rack
1.75 x 16.89 x 29.7 inches (4.44 x 42.90 x 75.43 cm)
1.75 x 16.89 x 31.52 inches (4.44 x 42.90 x 80.06 cm) with fans
36 lb (16 kg) two power supply modules, two network modules, 6 six fans
30 lb (13.6 kg) no power supply modules, no network modules, no fans
100 GB
The storage SSD must be
Note
installed in slot 1. Slot 2 is
reserved for the optional MSP
SSD.
Note
If you are running Firepower
Threat Defense software, we
recommend that you upgrade to
the latest version (at least to
Version 6.1.0) to take
advantage of software updates
that enhance SSD management
performance and longevity.
800 GB
Note
The optional MSP SSD must be installed in slot 2.
64 GB
128 GB
Cisco Firepower 4110, 4120, 4140, and 4150 Hardware Installation Guide
QSFP-4X10G-AC
QSFP-H40G-AOC
4140
200 GB
The storage SSD must be
Note
installed in slot 1. Slot 2 is
reserved for the optional MSP
SSD.
Note
If you are running Firepower
Threat Defense software, we
recommend that you upgrade to
the latest version (at least to
Version 6.1.0) to take
advantage of software updates
that enhance SSD management
performance and longevity.
256 GB
Hardware Specifications
4150
27