HyperTerminal

To run HyperTerminal, do the following:
1. Power up the SymNet1.
2. Launch HyperTerminal by selecting Start > Programs > Accessories > Communications >
HyperTerminal.
3. Type in <any name> in the Connection description dialog box and click OK.
4. Select the correct COM port and click OK.
5. Ensure the port settings are 57600 baud, 8 data bits, 1 stop bit, no parity, and no flow control. Click
OK.
6. Enter ? to display the menu.
7. Press 1 for the network settings.
8. Press 2 to change the network settings.
9. Type n to disable DHCP and then press Enter.
10. Enter the new IP addresses and then press Enter.
Note:
Obtain your network specific IP addresses from your network administrator.
11. After the Gateway address is entered the SymNet1 will reboot.
12. Remove power from the SymNet1 and disconnect the serial cable from your PC.