This Quick Start Manual provides instructions for advanced use of • When measuring the main circuit capacitor capacity, the DC voltage the FR-D700 series inverters. Incorrect handling might cause an is applied to the motor for 1s at powering off. Never touch the motor unexpected fault.
D700 QUICK START MANUAL CAUTION WIRING • When the breaker on the inverter input side trips, check for the • Do not install a power factor correction capacitor or surge wiring fault (short circuit), damage to internal parts of the inverter, suppressor/capacitor type filter on the inverter output side.
D700 QUICK START MANUAL FR-D710W-042 NOTE FR-D720-070 or more • Install the inverter on a strong surface securely and vertically with FR-D740-012 or more bolts. FR-D720S-070, 100 • Leave enough clearances and take cooling measures. • Avoid places where the inverter is subjected to direct sunlight, high temperature and high humidity.
Leave terminals P/+ and PR open. Also, never short between P/+ and PR. The FR-D700 series is a highly reliable product, but incorrect 12. Do not apply a voltage higher than the permissible voltage to the peripheral circuit making or operation/handling method may shorten inverter I/O signal circuits.
D700 QUICK START MANUAL Backup method outside the inverter Even if the interlock is provided by the inverter status signal, enough Interloc Power R/L1 failsafe is not ensured depending on the failure status of the inverter supply S/L2 itself. For example, even if the interlock is provided using the inverter...
Page 8
D700 QUICK START MANUAL Parameter Parameter Setting Range Initial Value Setting Range Initial Value Name Name DC injection brake operation time 0 to 10s 0.5s Energy saving control selection 0, 9 0 0, 9 0 DC injection brake operation voltage...
Page 9
D700 QUICK START MANUAL Parameter Parameter Setting Range Initial Value Setting Range Initial Value Name Name Parameter for manufacturer setting. Do not set. 0 to 400Hz, Multi-speed setting (speed 11) 9999 9999 Output current detection level 0 to 200% 150%...
D700 QUICK START MANUAL 4. The parameter number in parentheses is the one for use with the operation Parameter Setting Range Initial Value panel (FR-PA02-02) for the FR-E500 series or parameter unit (FR-PU04/ FR- Name PU07). Current average value monitor Rated inverter 5.
Page 11
D700 QUICK START MANUAL n BASIC OPERATION (FACTORY SETTING) n EASY OPERATION MODE SETTING (EASY SETTING MODE) Setting of Pr. 79 Operation mode selection according to combination of Operation mode switchover the start command and speed command can be easily made.
Page 12
D700 QUICK START MANUAL n CHANGING THE PARAMETER SETTING VALUE Change the Pr. 1 Maximum frequency setting. Screen at powering on The monitor display appears. PU indication is lit. Press to choose the PU operation mode. PRM indication is lit.