Philips CCS 800 Service Manual page 17

Hide thumbs Also See for CCS 800:
Table of Contents

Advertisement

Nominal level and bandwidth
Insert a sine wave signal to the AUDIO-CONTR via M1 related to M2 and measure the output signal between M59 and
M57.
G1
+
Audio Contr.
Sine-Wave
GND
Generator
-
Nominal level
-36 dBV (15.8 mVrms)
Bandwidth
-36 dBV (15.8 mVrms)
Bandwidth
-36 dBV (15.8 mVrms)
LBB 3310/00, 3330/00 and 3331/00
4822 861 11006
90 ... 264V AC
~
~
AC
24V DC
X10
Trunk
X11
M1
SHIELD
M2
(GND)
M110
M111
X110
6
9
Line-IN
settings for G1
Amplitude
Power Supply
PCB CPSU
Loudspeaker
25Ω
(GND)
M121
M122 M124
M150 M151
4
8
2
7
Rec-IN
Rec-IN
Telephone
L
R
Figure 3
Frequency
1 kHz
-7.8 dBV +/- 1.5dB (72 dB SPL)
125 Hz
-8 dBV +/- 2 dB related to nom level at 1 kHz.
12.5 kHz
-3dB +/- 1.0dB related to nom. level at 1kHz.
page: 15
SERVICE MANUAL
X205 M59
+
M57
-
(GND)
2
5
X150
IN
measurement results for A1
sound level
A1
V
003_003.cdr
Date of issue:
July 1998

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents