Optical Parts Disassemblies
Optical Unit Top removal
1
Remove 7 screws to take the Optical Unit Top off upward.
Condenser Lens disassembly
1
Remove 2 hex screws
2
B
Release 4 hooks
to take the Lens off from the holder.
A
and take the Condenser Lens ass'y.
A
A
Condenser Lens
Fig.6-
1
Fig.5
* Lens should be placed
as the flat surface side
comes to the holder
side.
-16-
B
Holder
Condenser Lens
Fig.6-
2