Sanyo PLC-XW55A Service Manual page 34

Chassis: kr6-xw55a00, kp6-xw50a00
Hide thumbs Also See for PLC-XW55A:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
148 V-Line Shading Comp. Value
Setting [B4 dot]
V-Line Shading Comp. Value
149
Setting [B5 dot]
V-Line Shading Comp. Value
150
Setting [B6 dot]
Group 200 Option
0 Logo Prohibition (Forced No Brand)
1 RS232C Baudrate
2 PJLink Enable
3 Shipping Setting
4 CABLE SW
5 PW Debug Command Enable
6 Device Refresh Disable
7 Device Access Disable
20 Projector Time Reset
21 Lamp Warning Time (NORMAL)
22 Lamp Warning Time (ECO)
23 Lamp Warning Time (HIGH)
30 Lamp life test enable
31 Lmap On time(for life test)
32 Lamp Off time(for life test)
33 Lamp total time(for life test)
40 PreScaler
41 Htime
52 Lamp Counter reset Times
54 Factory Default Execute Times
55 Motor Disable
56 Menu Position
57 Menu Position
60 Spread Spectrum Enable
61 Spread Spectrum Frequency
62 Spread Spectrum Amplitude
Group 201 Option (signal)
0 FrameLock Option
2 Field Sense Invert Enable
3
4 Sub Image Enable
6 Zoom Accelerator Enable
7 DZoom Reset by Keystone
8 Stability Count
9 Sensivity for Signal Lost (HSYNC)
10 Sensivity for Signal Lost (VSYNC)
11 Keystone Filter Center Value
Group 210 LampContorl
0 DIMMER_CTRL_LEVEL1
1 DIMMER_CTRL_LEVEL2
2 DIMMER_CTRL_LEVEL3
3 DIMMER_CTRL_LEVEL4
4 DIMMER_CTRL_LEVEL5
5 DIMMER_CTRL_LEVEL6
Function
Normal-Mount / Rear-Ceiling
Normal-Mount / Rear-Ceiling
Normal-Mount / Rear-Ceiling
Logo Prohibition (0: Menu, 1: Forced, 2:
China, 3-9: not used)
Baud Rate
PJLink
Long Cable
Lamp Life at Normal Mode (Warning Time at
Normal)
Lamp Life at Eco Mode (Warning Time at
Eco)
Lamp Life at High Mode (Warning Time at
High)
For test purpose
For test purpose
For test purpose
Reset Times of Lamp Counter
Reset times of Fanctory Default
0: On, 1: Off
Move menu (X asis)
Move menu (Y asis)
Count Value of V-missing
Only used this value for No Signal
Judgement(Hz)
Only used this value for No Signal
Judgement(Line)
Luminance Level 1 Data for Dimmer: Dim
Level 1 at the less than the Value
Luminance Level 2 Data for Dimmer: Dim
Level 2 at the less than the Value
Luminance Level 3 Data for Dimmer: Dim
Level 3 at the less than the Value
Luminance Level 4 Data for Dimmer: Dim
Level 4 at the less than the Value
Luminance Level 5 Data for Dimmer: Dim
Level 5 at the less than the Value
Luminance Level 6 Data for Dimmer: Dim
Level 6 at the less than the Value
Initial
16 /16
16 /16
16 /16
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
80
100
0
0
1
0
0
5
350
3
16
9
18
26
35
44
53
-34-
Range
Note
0 - 31
0 - 31
0 - 31
0 - 2
Effective after AC On
0 - 2
0: 19200bps, 1: 9600bps, 2: 115200bps
0 - 1
0:Disable 1:Enable
0 - 20
Default set when the value is set to 10
0 - 10
0: Disable, 1: Enable
0:Disable (Sanyo Serial Command Eanble)
0 - 1
1: Enable (PW Debug Mode)
0:Enable, 1:Disable
0 - 1
No last memory
0:Enable (Normal), 1:Disable
0 - 1
No last memory
Projector Time is cleared when the value is
0 - 20
set to 10
500 - 8000
500 - 8000
500 - 8000
0:Disable 1:Enable, for safety test only
0-255
n/a
0-65535
n/a
0 - 255
Read only
0 - 255
Read only
0 - 1
0 - 1024
0 - 1024
0 - 1
0: Off, 1: On
0 - 500
0 - 300
0: FrameLockOFF at PC signal
0 - 1
1: FrameLockON at PC signal and 47Hz
(Vfreq) ~ Panel frequency of input signal
Reverse Processing of FLDINVSetting Value
0: Disable - Used FLDINV Setting Value
0 - 1
1: Enable - Used Reversed FLDINV Setting
Value
0:Disable (Service Adjustment Dsiable,
0 - 1
Used all the Center Values
1:Enable (Service Adjustment Enable)
0:Zoom Accelerator OFF,
0 - 1
1:Zoom Accelerator ON
No last memory
0:Enable (Normal), 1:Disable (Dzoo is not
0 - 1
cancelled even if Keystone is cancelled)
No last memory
0 - 255
0 - 65535
0 - 255
0 - 30
0 - 255
Philips 200W
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255