Philips MCM7000/12 Service Manual page 7

Hide thumbs Also See for MCM7000/12:
Table of Contents

Advertisement

4. Technical Specifications
Power Supply
4.1.1
Type and versions
Build-inSMPS will be used for all models and stroke versions.
All using figure '8' socket, will cater for all versions:
Versions
Region/Country
12
/
05
EUROPE/UK
37
NAFTA
LATAM
55
98
APAC
94
India
All requirements per defined for each country should be met with sufficient testing.
4.1.2
Surge Immunity (Lightning Test)
The product shall withstand mains interference's of:
Differential mode:
2kV/2 ohm criteria C for Europe.
6kV/12 ohm criteria C for NAFTA.
Parameters:
Bi-wave
Open circuit voltage: 2/50us
Short circuit current: 8/20us
From +/1kV to +/-2kV (for Europe) or +/-6kV (for Nafta) in steps of 1kV.
10 shots per combination.
One shot per minute.
Serial impedance: 2 Ohm for Europe, 12Ohm for Nafta.
Polarity and phase: Positive (phase 90º) & Negative (phase 270º)
Common mode:
6kV/2 ohm criteria C for Europe.
6kV/12 ohm criteria C for Nafta.
Parameters:
Ring-wave (100kHz)
From +/3kV to +/-6kV in steps of 1 kV.
10 shots per combination.
One shot per minute.
Serial impedance: 2 Ohm for Europe, 12Ohm for Nafta
Polarity and phase: Positive (phase 90º) & Negative (phase 270º)
Reference: IEC61000-4-5 and for USA: 3135 019 8029 Reliability evaluation.
Requirements:
Apparatus should fulfil the leakage current requirements of IEC60065 point 9.1.1 (UAN-D1631)
Defects or permanent deviations are not allowed.
Technical Specification and Connection Facilities
SMPS
1) 100 ~240Vac nom. (wide
range from 90V~264Vac limit)
used in all versions except
India.
Frequency: 47~63Hz.
2) 100 ~310Vac limit (India
compatible with up cost) used
only for India.
Frequency: 47~63Hz.
Detachable mains cords
EU(/12)round 2-pin & UK(/05) 3-pin
UL flat pin (non-polarized)
INMETRO certified round 2-pin
EU round 2-pin
EU (/12) round 2-pin
1-6

Advertisement

Table of Contents
loading

Table of Contents