Download Print this page

Sealey Autocharge1200HF Manual page 3

Compact auto smart charger

Advertisement

4.1.
mode Description.
Step 1 -
Voltage Selection 'V'
12V
24V
4.2.
9 stage charging.
Stage 1: Desulphation: Pulses of current and voltage.
Stage 2: Battery charge to 25% capacity using 50% constant current.
Stage 3: Battery charge to 50% capacity using max. current.
Stage 4: Battery charge to 75% capacity using constant voltage.
Stage 5: Analysis: Analysing power capacity.
Stage 6: Recond: If power capacity is low use Recond to attempt recovery.
Stage 7: Battery charge to 100% capacity using constant voltage.
Stage 8: Diagnosis: Check battery for 100% charged.
Stage 9: Maintenance: Battery fully charged.
4.3.
coNNectINg to the BatterY.
Note: the charger should be connected to the battery before connecting to mains supply.
4.3.1.
The output cable from the charger terminates in a polarity conscious socket into which the two alternative leads can be connected.
4.3.2.
one lead set has two colour coded battery clamps which can be quickly attached to and detached from the battery posts.
The second lead is for semi permanent connection to the battery via eyelets.
4.4.
chargINg a NegatIVe eartheD BatterY.
4.4.1.
ensure that the black clamp on the clamp lead is not touching the battery or the fuel line.
4.4.2.
Connect the positive (+) red clamp to the positive (+) battery post and connect the negative (-) black clamp to the negative (-) battery
post or vehicle chassis.
4.5.
chargINg a posItIVe eartheD BatterY.
4.5.1.
ensure that the red clamp on the clamp lead is not touching the battery or the fuel line.
4.5.2.
Connect the negative (-) black clamp to the negative (-) battery post and connect the positive (+) red clamp to the positive (+) battery
post or vehicle chassis.
4.6.
BatterY Not coNNecteD to a VehIcLe.
4.6.1.
Connect the (+) red clamp to the positive (+) battery post and connect the (-) black clamp to the negative (-) battery post.
4.7.
permaNeNt coNNectIoN to VehIcLe usINg eYeLet LeaD.
4.7.1.
Connect the eyelet on the red (+) wire to the positive (+) battery terminal and connect the eyelet on the black (-) wire to the negative (-)
battery terminal.
4.8.
chargINg moDe seLectIoN (see chart sectIoN 4.1).
4.8.1.
Choice of charging mode depends on battery rated voltage and battery type.
4.8.2.
When charging mode is selected, enter charging by pressing Enter/Exit button.
© Jack Sealey limited
Step 2 -
Step 3 -
Battery
Charging mode
Selection
Selection (A)
STd
2A
AGM
4A
Gel
8A
12A
AUTO
ReCond
WInTeR
SUPPLY
mAInTenAnCe
lITHIUM
4A
AUTO
mAInTenAnCe
Gel
2A
AGM
4A
STd
6A
AUTO
WInTeR
mAInTenAnCe
Original Language Version
Step 4 -
Charging status
Start charging
eNTER / EXIT
12V 2A Charging mode
12V 4A Charging mode
12V 8A Charging mode
12V 12A Charging mode
12V Auto mode
12V Recon mode
12V Winter mode
12V Supply mode
12V Maintain mode
12V 4A Charging mode
12V Auto mode
12V Maintain mode
24V 2A Charging mode
24V 4A Charging mode
24V 6A Charging mode
24V Auto mode
24V Winter mode
24V Maintain mode
AUTOCHARGE1200HF
Applicable battery
capacity (Ah)
1.3 - 60Ah
2.6 - 120Ah
4 - 250Ah
5 - 400Ah
/
/
/
/
/
2.6 - 120Ah(LFP)
/
/
1.3-60Ah
2.6-120Ah
3.3-200Ah
/
/
Issue 1 22/08/18

Advertisement

loading