Mitsubishi Electric MELPRO-A Series Instruction Manual page 8

Directional earth fault relay
Hide thumbs Also See for MELPRO-A Series:
Table of Contents

Advertisement

Vibration
Maximum acceleration: 300m/s
Shock
Direction: 3 directions in forward/backward, right/left, and up/down
Criteria: No abnormality when applying two shocks in each direction
Test circuit: Between all circuits and earth (E terminal), between separate circuits (except for I
Insulation
circuits), and between the poles of contacts
resistance
Criteria: More than 10MΩ by DC500V megger.
(Note) The test is held under the condition that relative humidity is less than 80%.
Between all circuits and earth (E terminal): AC2000V, for 1 minute
Withstand voltage
Between separate circuits (except for I
Between the poles of contacts (a11-a12, a21-a22): AC1000V for 1 minute
Apply standard waveform (1.2/50 μs) to positive/negative pole for 3 times respectively.
Between ZCT primary and earth: 60kV
Lightning impulse
Between all circuits of the relay and earth (E terminal): 4.5kV
withstand voltage
Between EVT/ZCT secondary and control circuit: 4.5kV
Between contact terminal and power supply terminal: 3.0kV
Between terminals of power supply: 3.0kV
Apply damped oscillatory wave prescribed in JIS C 4609 for 2 seconds.
・Between EVT/ZCT secondary and earth (E terminal)
・Between power supply terminal and earth (E terminal)
・Between terminals of power supply
Noise-proof
・Between contact terminal and earth (E terminal)
Setting: Minimum operation value and minimum operating time
Input: Rated auxiliary power supply, I
Criteria: No malfunction
Intermittently irradiate radio waves to the front panel of the relay with a transceiver of 150MHz or 400MHz
band (5W output) from a distance of 0.5m.
Radio disturbance
Setting: Minimum operation value and minimum operating time
Input: Rated auxiliary power supply, I
Criteria: No malfunction
Contact capacity
Note) For details, refer to JIS C 4609 (1990).
Peak-to-peak amplitude mm
(Acceleration m/s
Frequency
(Hz)
Forward/
Right/left
backward
10
5 (10)
16.7
Making
(Closing)
2
)
Up/down
2.5 (5)
0.4 (2)
2
-V
circuits): AC2000V, for 1 minute
0
0
and V
= 0
0
0
and V
= 0
0
0
DC110V 15A (L/R=0ms)
DC220V 10A (L/R=0ms)
AC110V 10A (cosφ=0.1)
8
Setting: Minimum operation value and
Vibration
minimum operating time
time
Input: Rated auxiliary power supply
(s)
I
and V
0
Criteria:
No
30
abnormal indication
600
DC110V 0.3A (L/R=7ms)
Breaking
AC110V 5A (cosφ=0.1)
(Opening)
AC220V 1A (cosφ=0.1)
= 0
0
malfunction
and
no
-V
0
0
JEP0-IL9559