Mitsubishi Electric 800 Series Instruction Manual page 96

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

4.3
Fault history and the list of fault displays
For details, refer to the FR-A800 Instruction Manual (Detailed).
Abbreviation
LOCD
Password locked
Er1 to Er4
Parameter write error
Er8
rE1 to rE8
Copy operation error
Err.
Error
OL
Stall prevention (overcurrent)
oL
Stall prevention (overvoltage)
TH
Electronic thermal relay function pre-alarm
PS
PU stop
MT1 to MT3
Maintenance signal output
SL
Speed limit indication
Continuous operation during communication
CF
fault
SA
Safety stop
UF
USB host error
HP1
Home position return setting error
HP2
Home position return uncompleted
HP3
Home position return parameter setting error
EHR
Ethernet communication fault

FN
Fan alarm
FN2
Internal-circulation fan alarm
E.OC1
Overcurrent trip during acceleration
E.OC2
Overcurrent trip during constant speed
E.OC3
Overcurrent trip during deceleration or stop
Regenerative overvoltage trip during
E.OV1
acceleration
Regenerative overvoltage trip during
E.OV2
constant speed
Regenerative overvoltage trip during
E.OV3
deceleration or stop
Inverter overload trip (electronic thermal
E.THT
relay function)
Motor overload trip (electronic thermal relay
E.THM
function)
E.FIN
Heatsink overheat
E.IPF
Instantaneous power failure
E.UVT
Undervoltage
E.ILF
Input phase loss
E.OLT
Stall prevention stop
E.GF
Output side earth (ground) fault overcurrent
E.SOT
Loss of synchronism detection
E.LUP
Upper limit fault detection
E.LDN
Lower limit fault detection
E.LF
Output phase loss
E.OHT
External thermal relay operation
E.PTC
PTC thermistor operation
E.OPT
Option fault
E.OP1 to E.OP3 Communication option fault
E. 1 to E. 3
Option fault
Parameter storage device fault (control
E.PE
circuit board)
E.PUE
PU disconnection
E.RET
Retry count excess
Parameter storage device fault (main circuit
E.PE2
board)
E. 5 to E. 7
CPU fault
E.CPU
E.CTE
Operation panel power supply short circuit
E.P24
24 VDC power fault
E.CDO
Abnormal output current detection
E.IOH
Inrush current limit circuit fault
E.AIE
Analog input fault
E.OS
Overspeed occurrence
Name
If faults other than the above appear, contact your sales
representative.
Fault history and the list of fault displays
Abbreviation
E.OSD
Speed deviation excess detection
E.ECT
Signal loss detection
E.OD
Excessive position fault
E.MB1 to E.MB7 Brake sequence fault
E.EP
Encoder phase fault
E.MP
Magnetic pole position unknown
E.EF
External fault during output operation
E.BE
Brake transistor alarm detection
E.USB
USB communication fault
E.11
Opposite rotation deceleration fault
E.13
Internal circuit fault
E.PBT
E.SAF
Safety circuit fault
E.IAH
Abnormal internal temperature
E.LCI
4 mA input fault
E.PCH
Pre-charge fault
E.PID
PID signal fault
E.EHR
Ethernet communication fault

E.16 to E.20
User definition error by the PLC function
E----
Fault history
E.0
No fault records
EV
24 V external power supply operation
RD
Backup in progress
WR
Restoration in progress

"Fault" is displayed on the FR-LU08-01.
PROTECTIVE FUNCTIONS
Name
4
95

Advertisement

Table of Contents
loading

Table of Contents