Panasonic WH-ADC0309H3E5 Service Manual

Panasonic WH-ADC0309H3E5 Service Manual

Air-to-water hydromodule + tank
Hide thumbs Also See for WH-ADC0309H3E5:

Advertisement

Quick Links

This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to
service or repair the products dealt with in this service information by anyone else could result in serious injury or death.
There are special components used in this equipment which are important for safety. These parts are marked by
Diagrams, Circuit Board Diagrams, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced
with manufacturer's specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission of
manufacturer.
In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit.
Air-to-Water Hydromodule + Tank
Indoor Unit
WH-ADC0309H3E5
WARNING
IMPORTANT SAFETY NOTICE
PRECAUTION OF LOW TEMPERATURE
Outdoor Unit
WH-UD03HE5-1
WH-UD05HE5-1
WH-UD07HE5-1
WH-UD09HE5-1
Destination
Europe
Turkey
in the Schematic
!
© Panasonic Corporation 2016.

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic WH-ADC0309H3E5

  • Page 1 Do not modify the original design without permission of manufacturer. PRECAUTION OF LOW TEMPERATURE In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit. © Panasonic Corporation 2016.
  • Page 2: Safety Precautions

    Safety Precautions  Read the following “SAFETY PRECAUTIONS” carefully before installation of Air-To-Water Hydromodule + Tank (here after referred to as “Tank Unit”).  Electrical works and water installation works must be done by licensed electrician and licensed water system installer respectively.
  • Page 3 WARNING 19. During pump down operation, stop the compressor before remove the refrigeration piping. Removal of refrigerant piping while compressor is operating and valves are opened will cause suck-in of air, abnormal high pressure in refrigerant cycle and result in explosion, injury etc. 20.
  • Page 4: Specifications

    Specifications WH-ADC0309H3E5 WH-UD03HE5-1 Item Unit Outdoor Unit Performance Test Condition EN 14511 Condition A35W7 (Ambient/Water) 3.20 Cooling Capacity BTU/h 10900 kcal/h 2750 3.08 Cooling EER kcal/hW 2.64 Condition A7W35 A2W35 (Ambient/Water) 3.20 3.20 Heating Capacity BTU/h 10900 10900 kcal/h 2750 2750 5.00...
  • Page 5 Item Unit Outdoor Unit ø Single Power Source (Phase, Voltage, Cycle) Condition A35W7 A7W35 A2W35 (Ambient/Water) Input Power Cooling: 1.04 Heating: 0.64 Heating: 0.90 Maximum Input Power For Heatpump System 2.59 Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 1Ø...
  • Page 6 Item Unit Indoor Unit Volume Expansion Vessel Capacity of Integrated Electric Heater / OLP TEMP kW / °C 3.00 / 80 Tank Volume (Spec / Nett) 200 / 185 Max. Tank Water Set Temperature °C Tank Coil Surface Heat / Cool Maximum Working Pressure Tank Circuit...
  • Page 7 WH-ADC0309H3E5 WH-UD05HE5-1 Item Unit Outdoor Unit Performance Test Condition EN 14511 Condition A35W7 (Ambient/Water) 4.50 Cooling Capacity BTU/h 15300 kcal/h 3870 2.69 Cooling EER kcal/hW 2.32 Condition A7W35 A2W35 (Ambient/Water) 5.00 4.20 Heating Capacity BTU/h 17100 14300 kcal/h 4300 3610 4.63...
  • Page 8 Item Unit Outdoor Unit ø Single Power Source (Phase, Voltage, Cycle) Condition A35W7 A7W35 A2W35 (Ambient/Water) Input Power Cooling: 1.67 Heating: 1.08 Heating: 1.35 Maximum Input Power For Heatpump System 2.59 Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 1Ø...
  • Page 9 Item Unit Indoor Unit Protection Device Residual Current Circuit Breaker (30) Volume Expansion Vessel Capacity of Integrated Electric Heater / OLP TEMP kW / °C 3.00 / 80 Tank Volume (Spec / Nett) 200 / 185 Max. Tank Water Set Temperature °C Tank Coil Surface Heat / Cool...
  • Page 10 WH-ADC0309H3E5 WH-UD07HE5-1 Item Unit Outdoor Unit Performance Test Condition EN 14511 Condition A35W7 (Ambient/Water) 6.00 Cooling Capacity BTU/h 20500 kcal/h 5160 2.63 Cooling EER kcal/hW 2.26 Condition A7W35 A2W35 (Ambient/Water) 7.00 6.55 Heating Capacity BTU/h 23900 22300 kcal/h 6020 5630 4.46...
  • Page 11 Item Unit Outdoor Unit ø Single Power Source (Phase, Voltage, Cycle) Condition A35W7 A7W35 A2W35 (Ambient/Water) Input Power Cooling: 2.28 Heating: 1.57 Heating: 1.96 Maximum Input Power For Heatpump System 4.59 Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 1Ø...
  • Page 12 Item Unit Indoor Unit Protection Device Residual Current Circuit Breaker (30) Volume Expansion Vessel Capacity of Integrated Electric Heater / OLP TEMP kW / °C 3.00 / 80 Tank Volume (Spec / Nett) 200 / 185 Max. Tank Water Set Temperature °C Tank Coil Surface Heat / Cool...
  • Page 13 WH-ADC0309H3E5 WH-UD09HE5-1 Item Unit Outdoor Unit Performance Test Condition EN 14511 Condition A35W7 (Ambient/Water) 7.00 Cooling Capacity BTU/h 23900 kcal/h 6020 2.43 Cooling EER kcal/hW 2.09 Condition A7W35 A2W35 (Ambient/Water) 9.00 6.70 Heating Capacity BTU/h 30700 22800 kcal/h 7740 5760 4.13...
  • Page 14 Item Unit Outdoor Unit ø Single Power Source (Phase, Voltage, Cycle) Condition A35W7 A7W35 A2W35 (Ambient/Water) Input Power Cooling: 2.88 Heating: 2.18 Heating: 2.14 Maximum Input Power For Heatpump System 5.01 Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 1Ø...
  • Page 15 Item Unit Indoor Unit Protection Device Residual Current Circuit Breaker (30) Volume Expansion Vessel Capacity of Integrated Electric Heater / OLP TEMP kW / °C 3.00 / 80 Tank Volume (Spec / Nett) 200 / 185 Max. Tank Water Set Temperature °C Tank Coil Surface Heat / Cool...
  • Page 16 Features  Inverter Technology Energy saving  High Efficiency  Environment Protection Non-ozone depletion substances refrigerant (R410A)  Long Installation Piping Long piping up to 30 meter with height difference 20 meter Flexible 4-way piping for outdoor unit  Easy to use control panel Auto mode Holiday mode Dry concrete function...
  • Page 17 Main Components Connector name 1 Remote Controller c Flow Sensor Water Inlet 2 Water Pump d Water Pressure Gauge (From Space Heating/Cooling) 3 Control Board Cover e Front Plate 4 Main PCB Top Plate Water Outlet Single Phase RCCB/ELCB Right Plate (To Space Heating/Cooling) (Main Power) Left Plate...
  • Page 18: Outdoor Unit

    Outdoor Unit Air inlet (rear) Air inlet (side) Air outlet UD03_05HE5-1 Air inlet (rear) Air inlet (side) Air outlet UD07_09HE5-1...
  • Page 19: Indoor Unit

    Dimensions Indoor Unit <Top View> <Front View> <Side View> <Bottom View> Unit: mm...
  • Page 20 Outdoor Unit WH-UD03HE5-1 WH-UD05HE5-1 <Top View> Space necessary for 823.4 68.5 installation 21.9 (124) 53.4 10 cm 10 cm 100 cm Anchor Bolt Pitch 355 x 260 <Side View> <Side View> <Front View> Unit: mm...
  • Page 21 WH-UD07HE5-1 WH-UD09HE5-1 <Top View> <Side View> <Front View> <Side View> 318.5 (30) <Back View> Unit: mm...
  • Page 22: Refrigeration And Water Cycle Diagram

    Refrigeration and Water Cycle Diagram OUTDOOR UNIT INDOOR UNIT FLOOR HEATING AIR PURGE WATER OUTLET VALVE 3-WAY PRESSURE RELIEF VALVE VALVE WATER OUTLET TEMP. SENSOR STRAINER EXPANSION FLOW SWITCH (CU-UD07/09HE5-1) VALVE STRAINER BACKUP HEATER SANITARY HOT WATER OUTLET REFRIGERANT MUFFLER HEX WATER OUTLET TEMP.
  • Page 23: Wiring Connection Diagram

    Wiring Connection Diagram Indoor Unit EXTERNAL COMP. SW HEAT/COOL SWITCH SG SIGNAL SOLAR TEMP. SENSOR DEMAND SENSOR WATER TEMP. ZONE 1 WATER TEMP. ZONE 2 POOL TEMP. SENSOR BUFFER TANK SENSOR ROOM TEMP. ZONE 1 ROOM TEMP. ZONE 2...
  • Page 24 Outdoor Unit 8.2.1 WH-UD03HE5-1 WH-UD05HE5-1 TO INDOOR UNIT REACTOR TERMINAL ELECTRONIC CONTROLLER RAT1 RAT2 BOARD (BLACK) (WHITE) (RED) OUTDOOR AIR TEMP. SENSOR (THERMISTOR) (GRY) (GRY) t° CN-TH1 DATA (RED) (WHT) t° COMMUNICATION PIPING TEMP. SENSOR (THERMISTOR) NOISE FILTER CIRCUIT FUSE 103 AC-BLK CIRCUIT COMPRESSOR TEMP.
  • Page 25 WH-UD07HE5-1 WH-UD09HE5-1 ELECTRONIC CONTROLLER REACTOR REACTOR (CAPACITOR) FG1 (GREEN) FG2 (GREEN) CN-BLK CN-ACL RELAY (BLACK) DCP-OUT (BLACK) (WHITE) CAPACITOR NOISE FILTER CIRCUIT AC-BLK DCN-IN (BLACK) CIRCUIT (BLACK) CN-ACN (WHITE) AC-C (BLUE) DCN-OUT CN-WHT (BLACK) (WHITE) ELECTRONIC CONTROLLER (SUB) YELLOW AC-L AC-C DCN2 AC-BLK01...
  • Page 26 11. Inst tallation n Instru uction Field Supply y Accessorie es (Optional Part Model Specifications Maker Electromotoric Actuator SFA21/1 AC230V Siemens 2-way y valve kit *Cooli ng model 2-port Va VVI46/2 Siemens Wired PAW-A2W-RT TWIRED Room T Thermostat AC230V Wireles PAW-A2W-RTW WIRELESS Mixin...
  • Page 27: Piping Installation

    Finish by s sealing the s sleeve with p putty or 1.3.3 efrigerant t Piping In stallation caulking c compound at t the final sta This s Tank Unit is s designed fo or combinati on with nasonic Air-to o-Water Hea at Pump Outd door Unit.
  • Page 28 11.1.3.3.1 Cutting g and Fla ring the CAUTION Piping Do not ov ertighten, overti ightening may c cause gas leaka age. Pleas se cut using p pipe cutter a nd then remo  Make s ure to insula ate the water circuit pipes s to the bu...
  • Page 29   Pressure Re educing Valv ve (field supp ply) with The end of t this pipework k must be in such a way elow specific cation is stron ngly advised to be so that the o outlet is visib ble and canno ot cause any damage.
  • Page 30 5) Please note that the system’s pressure may rise Step 3: Vacuum test: slightly if the test is carried out on mid day, due to temperature rise. The inverse may happen when 1) Perform Vacuum test to check leak / moisture if there is temperature drop at night.
  • Page 31 11.1. .4 Conne ect the Cab ble to Tan nk Unit WARNING This s ection is for au thorized and lic censed electricia an only. Work b behind the Con ntrol Board Cove er secured by s screws must on nly be carried o under supervision of q...
  • Page 32 11.1.4.2 Wire Strip pping and Connecti ing Requir rement ire stripping Conductor Conductor nductor not Indoor/outdoor fully insert over insert ully insert connecting terminal board 5mm or more ACCEPT PROHIBITED ROHIBITED No l oose strand (gap between n insert wires) 11.1.4.3 Connectin ng Requir...
  • Page 33 Set the Pr ressure Relie ef Valve leve el “DOWN”. 1.6.3 xpansion Vessel Pr re Pressur hecking Pressure relief valve b Space Heat ting / Coolin  Expansion V Vessel with 1 10 L air capa acity and initia Lever pressure of 1 bar is insta alled in this T...
  • Page 34 11.1.7.2 Remote C Controller Wiring 11.1.7.4 Mountin ng The Rem mote Controll Tank Un For exposed d type Preparation n: Make 2 ho oles for screw ws using a d driver. Remote Cont troller Mount the top case. Mount th he bottom case to •...
  • Page 35: Maintenance

     11.1. .7.5 place The Remote C Controller For normal o operation, W Water Pressur re Gauge reading sho uld be in bet tween 0.05 M MPa and 0.3 MPa. If nece essary, adjus st the Water Pump  eplace the e existing Remo ote controlle r cover with...
  • Page 36 11.2 2 Outdoo or Unit Attac hed access ories tional Acces ssory Accessories part Qty. Accessories part Qty. Accessories pa Qty. ain elbow Banding strap Base Pan Heater CZ-NE2P (For UD0 03*E5* and UD05*E E5* only) CZ-NE3P (For UD0 07*E5* and UD09*E E5* only) (For UD07*E5* a UD09*E5* only...
  • Page 37 Model UD03*E5* a UD05*E5 UD07*E5* a UD09*E5 nit : mm) (Ancho or pitch)  After sele ecting the bes st location, s start installati on according g to Installati on Diagram. Fix th he unit on con ncrete or rigi d frame firm ly and horizo ontally by bo...
  • Page 38 11.2.4 Evacuation of the Equipment WHEN INSTALLING AN AIR-TO-WATER HEAT PUMP, BE SURE TO EVACUATE THE AIR INSIDE THE UNIT AND PIPES in the following procedure. Liquid side Indoor unit Outdoor unit Two-way valve Close Gas side Three-way valve Vacuum pump Close adaptor...
  • Page 39 11.2.5.1 Wire Strip pping and Connecti ing Requir rement Wire stripping Conductor not nductor over Conducto or fully Indoor/ou tdoor fully insert insert inse connectin g terminal board 5 mm m or more (gap be etween wires) CCEPT PROHIBITED PROHIBITED No loose str rand when insert (For UD07*E5...
  • Page 40 1.3.2 How w to fix ca able 11.3.2.1 Connectin ng with ex xternal dev vice (optio onal)  All conne ctions shall f follow to the local nationa al wiring stan ndard.  It is strong gly recomme ended to use e manufactur rer-recomme ended parts a...
  • Page 41 0 Demand s signal cable s shall be (2 x min 0.3 mm ), double in sulation laye er of PVC-she eathed or ru bber- sheathed cable. 1 SG signal cable shall b be (3 x min 0 0.3 mm ), do ouble insulati on layer of P...
  • Page 42 11.3.2.3 Connectio on of the m main PCB Zone 1 room sensor Outdoor air se ensor Tank sensor External contr Remote contr roller Boiler contact Extra pump C O N C O N C N L 2-way 3-way ional ermostat 1 valve valve ...
  • Page 43  his section e explains abou ut the externa al devices Dime ensions (mm) optional) reco ommended b by Panasonic c. Please ways ensure e to use the c correct exter rnal device blue Ø Ø6 uring system m installation.
  • Page 44  For opti ional pump. Tempe erature (°C) Resistance (kΩ Ω) Power s supply: AC23 30V/50Hz, < 500W 3.615 Recomm mended part t: Yonos 25/6 6: made by W Wilo 4.375 5.326 6.523 8.044 9.980 12.443 15.604  For opti ional mixing valve.
  • Page 45   On the wall near the Tank Unit, attach the Use the included cord clamp to fix the CN-CNT adaptor by screwing screws through the holes cable to the wall. in the back cover. Pull the cable around as shown in the diagram so that external forces cannot act on the connector in the adaptor.
  • Page 46 1) P-Q Q graph for d different pum p HEX duty P-Q (WH H-ADC0309H H3E5) x Duty: C5 Duty: 6F Min Du uty: 50 ter Flow Rate, Q (L L/min) 12.2. .2 Zone W Water Pum mp Contro Purpo ose: Water pump in nstall at each h zone to circ...
  • Page 47: Technical Data

    Technical Data Operation Characteristics WH-ADC0309H3E5 WH-UD03HE5-1 Heating Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 5.000 4.400...
  • Page 48 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 3.400 3.200 3.000 2.800 2.600 2.400 Outdoor Temperature (°C) 1.200 1.040 0.880...
  • Page 49 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 19°C Indoor water outlet temperature : 4°C Piping length : 7 m 4.400 4.200 4.000 3.800 3.600 3.400 Outdoor Temperature (°C) 1.200 1.080 0.960...
  • Page 50 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 23°C Indoor water outlet temperature : 18°C Piping length : 7 m 3.800 3.640 3.480 3.320 3.160 3.000 Outdoor Temperature (°C) 1.000 0.880 0.760...
  • Page 51 Heating Characteristics at Different Piping Length Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 3.300 3.240 3.180 3.120 3.060 3.000 Piping Length (m) 0.700 0.680 0.660...
  • Page 52 Cooling Characteristics at Different Piping Length Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 3.400 3.280 3.160 3.040 2.920 2.800 Piping Length (m) 1.100 1.060 1.020...
  • Page 53 WH-ADC0309H3E5 WH-UD05HE5-1 Heating Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 5.100 4.900 4.700 4.500 4.300 4.100...
  • Page 54 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 5.200 4.800 4.400 4.000 3.600 3.200 Outdoor Temperature (°C) 1.800 1.600 1.400...
  • Page 55 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 19°C Indoor water outlet temperature : 14°C Piping length : 7 m 6.400 5.920 5.440 4.960 4.480 4.000 Outdoor Temperature (°C) 1.700 1.540 1.380...
  • Page 56 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 23°C Indoor water outlet temperature : 18°C Piping length : 7 m 5.800 5.520 5.240 4.960 4.680 4.400 Outdoor Temperature (°C) 1.600 1.440 1.280...
  • Page 57 Heating Characteristics at Different Piping Length Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 5.200 5.080 4.960 4.840 4.720 4.600 Piping Length (m) 1.100 1.080 1.060...
  • Page 58 Cooling Characteristics at Different Piping Length Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 5.00 0 4.80 0 4.60 0 4.40 0 4.20 0 4.00 0 Piping Length (m)
  • Page 59 WH-ADC0309H3E5 WH-UD07HE5-1 Heating Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 9.000 8.000 7.000 6.000 5.000 4.000...
  • Page 60 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 8.000 7.000 6.000 5.000 4.000 3.000 (°C) Outdoor Temperature 5.000 4.000...
  • Page 61 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 19°C Indoor water outlet temperature : 14°C Piping length : 7 m 10.000 9.000 8.000 7.000 6.000 5.000 (°C) Outdoor Temperature 5.000 4.000...
  • Page 62 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 23°C Indoor water outlet temperature : 18°C Piping length : 7 m 8.000 7.000 6.000 5.000 4.000 3.000 (°C) Outdoor Temperature 5.000 4.000...
  • Page 63 Heating Characteristics at Different Piping Length Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 9.000 8.000 7.000 6.000 5.000 4.000 Piping Length (m) 3.000 2.500 2.000...
  • Page 64 Cooling Characteristics at Different Piping Length Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 6.500 6.000 5.500 5.000 4.500 4.000 Piping Length (m) 2.500 2.400 2.300...
  • Page 65 WH-ADC0309H3E5 WH-UD09HE5-1 Heating Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 10.000 9.000 8.000 7.000 6.000 5.000...
  • Page 66 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 9.000 8.000 7.000 6.000 5.000 4.000 (°C) Outdoor Temperature 5.000 4.000...
  • Page 67 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 19°C Indoor water outlet temperature : 14°C Piping length : 7 m 11.000 10.000 9.000 8.000 7.000 6.000 (°C) Outdoor Temperature 5.000 4.000...
  • Page 68 Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 23°C Indoor water outlet temperature : 18°C Piping length : 7 m 9.000 8.000 7.000 6.000 5.000 4.000 (°C) Outdoor Temperature 5.000 4.000...
  • Page 69 Heating Characteristics at Different Piping Length Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 11.000 10.000 9.000 8.000 7.000 6.000 Piping Length (m) 3.500 3.000 2.500...
  • Page 70 Cooling Characteristics at Different Piping Length Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 7.500 7.000 6.500 6.000 5.500 5.000 Piping Length (m) 3 .10 0 3 .00 0 2 .90 0...
  • Page 71: Heating Capacity Table

    Heating Capacity Table WH-ADC0309H3E5 WH-UD03HE5-1 Water Out (°C) Input Input Input Input Input Input Capacity Capacity Capacity Capacity Capacity Capacity Outdoor Air (°C) Power Power Power Power Power Power 3200 1260 3200 1390 3100 1520 3000 1640 2800 1780 2750...
  • Page 72: Cooling Capacity Table

    Cooling Capacity Table WH-ADC0309H3E5 WH-UD03HE5-1 Water Out (°C) Outdoor Air (°C) Capacity (W) Input Power (W) Capacity (W) Input Power (W) Capacity (W) Input Power (W) 2400 4400 3700 3200 4100 3500 3200 1040 3900 1070 3300 2900 1200 3500...

This manual is also suitable for:

Wh-ud03he5-1Wh-ud05he5-1Wh-ud07he5-1Wh-ud09he5-1

Table of Contents