1. Safety Precautions Read the following “SAFETY PRECAUTIONS” carefully before installation. Electrical work must be installed by a licensed electrician. Be sure to use the correct rating and main circuit for the model to be installed. The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below.
Page 3
WARNING Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury. This equipment is strongly recommended to be installed with Residual Current Device (RCD) on-site according to the respective national wiring rules or country–specific safety measures in terms of residual current.
Page 4
CAUTION Installation work. It may need two or more people to carry out the installation work. The weight of Indoor Unit might cause injury if carried by one person.
Page 6
Item Unit Outdoor Unit Type Propeller Fan Material Motor Type DC (8-poles) Input Power — Output Power Cooling: 700 Fan Speed Heating: 640 Fin material Aluminium (Pre Coat) Fin Type Corrugated Fin Heat Exchanger Row × Stage × FPI 2 × 30 × 17 Size (W ×...
Page 7
Item Unit Indoor Unit Type Brazed Plate No. of Plates Hot Water Coil Size (H × W × L) 82 × 93 × 325 Cooling: 20.1 (1.2) Water Flow Rate l/min (m Heating: 25.8 (1.5) Pressure Relief Valve Water Circuit Open: 300, Close: 266 and below Flow Switch Electronic Sensor...
Page 8
Features Inverter Technology - Energy saving High Efficiency Compact Design Environment Protection - Non-ozone depletion substances refrigerant (R410A) Long Installation Piping - Long piping up to 15 meter with height difference 5 meter - Flexible 4-way piping for outdoor unit ...
Main Components Cabinet front plate Cabinet side plate (2 pieces) Remote controller Single Phase RCCB/ELCB (Main Power) Single Phase RCCB/ELCB (Backup Heater) Control board cover Control board Flow sensor Air purge valve Backup heater Overload protector (2 pieces) Expansion vessel Pressure relief valve Water pressure gauge Water filter...
Dimensions Indoor Unit <Top View> <Front View> <Side View> 58.9 141.9 326.9 <Bottom View> 424.5 404.1 54.6 69.5 437.3 Relative position between the indoor unit and the installation plate <Front View> More than 375 More than 375 Wall Wall Installation plate Indoor Unit body...
Wiring Connection Diagram Indoor Unit EXTERNAL COMP. SW HEAT/COOL SWITCH SG SIGNAL SOLAR TEMP. SENSOR DEMAND SENSOR WATER TEMP. ZONE 1 WATER TEMP. ZONE 2 POOL TEMP. SENSOR BUFFER TANK SENSOR ROOM TEMP. ZONE 1 ROOM TEMP. ZONE 2...
Page 14
Tank Sensor Resistant Vs Temperature How To Fix Cable 16000 14000 12000 Connecting with external 10000 device (optional) 8000 6000 All connections shall follow to the local national 4000 wiring standard. 2000 It is strongly recommended to use manufacturer- recommended parts and accessories for -30 -20 -10 installation.
Page 15
valves, water pumps and thermistors in zone 1 and zone 2 to each terminals in optional PCB. Temperature of each zone can be controlled independently by remote controller. 2. Pump zone 1 and zone 2 cable shall be (2 × min 1.5 mm ), of type designation 60245 IEC 57 or heavier.
Page 16
PCB Tank sensor AW-A2W-TSOD (Total cable length Outdoor air sensor shall be 30m or less) Room sensor Tank sensor Please use Panasonic specified part Outdoor air sensor Tank OLP Connection of Optional PCB Buffer tank sensor (CZ-NS4P) Pool water sensor...
This section explains about the external devices Insert the sensor into the sensor pocket and paste (optional) recommended by Panasonic. Please it on the solar panel surface. always ensure to use the correct external device during system installation.
Page 18
For optional pump. For optional mixing valve. Power supply: AC230V/50Hz, <500W Power supply: AC230V/50Hz (input open/output Recommended part: Yonos 25/6: made by Wilo close) Operating time: 30s~120s Recommended part: 167032: made by Caleffi...
Page 23
Maximum pump speed setting on remote control Standard pump speed is automatically controlled to get the designed water temperature different between water inlet and outlet (ΔT). Instead of setting the standard pump speed, maximum pump speed is manually adjusted by the installer according to water circuit pressure drop.
Page 24
WH-SDC09H3E5 WH-UD09HE5 Heating Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 10.000 9.000 8.000 7.000 6.000 5.000...
Page 25
Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 9.000 8.000 7.000 6.000 5.000 4.000 Outdoor Temperature (°C) 5.000 4.000 3.000...
Page 26
Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 19°C Indoor water outlet temperature : 14°C Piping length : 7 m 11.000 10.000 9.000 8.000 7.000 6.000 Outdoor Temperature (°C) 5.000 4.000 3.000...
Page 27
Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 23°C Indoor water outlet temperature : 18°C Piping length : 7 m 9.000 8.000 7.000 6.000 5.000 4.000 Outdoor Temperature (°C) 5.000 4.000 3.000...
Page 28
Heating Characteristics at Different Piping Length Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 11.000 10.000 9.000 8.000 7.000 6.000 Piping Length (m) 3.500 3.000 2.500...
Page 29
Cooling Characteristics at Different Piping Length Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 7.500 7.000 6.500 6.000 5.500 5.000 Piping Length (m) 3.100 3.000 2.900...