LG LV181HV4 Installation Manual page 10

Single zone vertical air handling unit 18,000 - 48,000 btu/h
Table of Contents

Advertisement

GENERAL DATA
Table 2: Vertical Air Handling Unit General Data, continued.
Type
System (Model) (Indoor Unit / Outdoor Unit) LV181HV4
Unit Data
Refrigerant Type
3
Additional Refrigerant Charge (oz./ft.)
Refrigerant Control
Indoor Unit Sound Pressure Level (dB(A))
(H/M/L)
4
Outdoor Unit Sound Pressure Level (dB(A))
(Cool/Heat)
4
Indoor Unit Net / Shipping Weight (lbs.)
Outdoor Unit Net / Shipping Weight (lbs.)
Power Wiring / Communications Cable (No.
x AWG)
2
Power Supply (No. x AWG)
Compressor (Type x Qty.)
Dehumidification Rate (pts./hr.)
Fan
Indoor Unit Type x Qty.
Outdoor Unit Type x Qty.
Motor / Drive
Airflow Rate
Indoor Unit (H / M / L [CFM])
Outdoor Unit (CFM)
Factory Set (High) External Static
Pressure (in.wg)
Piping
Liquid (in.)
Vapor (in.)
Indoor Unit Condensate Drain O.D. / I.D.
(in.)
Minimum / Maximum Pipe Length (ft.)
Piping Length (no additional refrigerant, ft.)
Maximum Elevation Difference (ft.)
EEV: Electronic Expansion Valve, IDU: Indoor Unit, ODU: Outdoor Unit. This unit comes with a
dry helium charge.
This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft
level difference between outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF
wet bulb (WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF
wet bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
Cooling range can be extended from 5°F down to -4°F
1 Power Input is rated at high speed.
using the Low Ambient Wind Baffle Kit (sold separately)
2 All
communication / connection (power) cable from the outdoor unit to the indoor unit
10
LV241HV4
(LVN181HV4/
(LVN241HV4/
LUU189HV)
LUU249HV)
35 / 33 / 30
36 / 34 / 30
48 / 52
48 / 52
123.5 / 135.1
123.5 / 135.1
129 / 141
130.0 / 143.3
3 x 12
3 x 12
Twin Rotary x 1
Twin Rotary x 1
3.1
4.0
Propeller x 1
Propeller x 1
ECM (Electronically Commutated Motor)
640 / 580 / 480
710 / 640 / 480
2,048
2,048
Constant CFM @ 0.1" ~ 1.0" ESP
6.6 / 164
6.6 / 164
5
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Vertical Air Handling Unit
LV361HV4
LV420HV
(LVN361HV4/
(LVN420HV/
LUU369HV)
LUU428HV)
R410A
0.43
EEV
44 / 41 / 39
48 / 45 / 44
52 / 54
52 / 54
129 / 140
165 / 188
198.9 / 223.1
203 / 232
4 x 14
3 x 10
3 x 10
Scroll x 1
Twin Rotary x 1
5.1
4.3
Sirocco
Propeller x 2
990 / 880 / 800 1,260 / 1,100 / 1,000 1,400 / 1,260 / 1,000
1,942 x 2
1,942 x 2
3/8
5/8
Primary &
Secondary: 3/4 FPT
6.6 / 246
6.6 / 246
24.6
98.4
are field supplied and is to be a minimum four-conductor, 14 AWG, stranded, shielded or
unshielded (if shielded, it must be grounded to the chassis of ODU only), and must comply
with applicable local and national codes.
3 Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or
destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under
section 608 of CAA.
4 Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and
are the same in both cooling and heating mode. These values can increase due to ambient
conditions during operation.
5 Piping lengths are equivalent.
LV480HV
(LVN480HV/
LUU488HV)
49 / 48 / 44
52 / 54
165 / 188
203 / 232
3 x 10
Twin Rotary x 1
5.2
Propeller x 2
Propeller x 2
Brushless Digitally Controller / Direct
1,942 x 2
0.3
0.3
6.6 / 246