Brake disc & lining cleaner 15ltr

Advertisement

4. OPERAtION
WArnInG! Ensure that you read, understand and apply the safety instructions in section 1.
4.1.
Filling.
4.1.1. Open the pressure relief valve to ensure that there is no pressure in the lower tank (there is a valve between the upper and lower
tanks which is closed when the lower tank is pressurized and open when it is not).
4.1.2. fill the lower tank with Brake Cleaning solvent by pouring it into the drain pan, from where it will run through the upper tank into the
lower tank. Check solvent level in sight tube. Approximate fill volume is 15 litres.
4.2.
Operation.
4.2.1. Position the cleaner pan (large or small to suit application) under the brake assembly and tighten the pipe clamp screw.
4.2.2. Connect the brush hose to either the direct or impulse outlet, as required.
4.2.3. Check that the inlet valve and relief valves are closed and then connect an air line to the air inlet. supply pressure should not exceed
90psi.
4.2.4. Turn on the air supply, open the inlet valve and adjust the pressure regulator to give a suitable solvent flow from the brush (typically
1 to 2 bar). DO nOT exceed 90psi (6 bar).
4.2.5. Carry out the cleaning operation. The dirty fluid will flow from the pan into the upper tank. The valve between the tanks will prevent the
fluid from entering the lower tank until the lower tank pressure is vented.
4.2.6. When cleaning is finished, close the air inlet valve and open the relief valve. The used fluid in the upper tank will now flow into the
lower tank, passing through the upper tank filter.
note:
If necessary the unit can be operated disconnected from the air supply - once the lower tank has been pressurized close the inlet
valve and disconnect the air supply. The cleaner will now operate as normal until the pressure in the lower tank falls too low to provide
an adequate solvent flow.
4.3.
Emptying.
WARNING! Ensure that the cleaner is disconnected from the air supply and that the
relief valve is open.
4.3.1. Place a suitable container under the lower tank and then remove the drain plug.
4.3.2. When the tank is drained replace the drain plug.
IMPORtANt! Dispose of waste solvent in accordance with local authority regulations.
4.4.
Filter.
regularly remove and clean the upper tank filter.
4.4.1. remove drain pipe from upper tank cover.
4.4.2. Open the four cover retaining clips and remove the cover.
4.4.3. Lift out the filter and clean with soapy water. Thoroughly rinse and dry.
4.4.4. Install the cleaned dry filter, replace and clip down the cover and refit the drain pipe.
Parts support is available for this product. to obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORtANt: no liability is accepted for incorrect use of this product.
WARRANtY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMAtION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
sales@sealey.co.uk or phone 01284 757500.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury st. Edmunds, suffolk,
IP32 7AR
Original Language Version
01284 757500
Web
01284 703534
email
www.sealey.co.uk
sales@sealey.co.uk
Vs2000
Issue: 3 - 20/04/12

Advertisement

loading