Rotary sprinklers

Advertisement

Quick Links

Introduction
The FLX34 and FLX54 series full-circle rotary sprinklers are
designed specifically for golf course applications.
Manufactured from durable, high-strength engineering plastic and
stainless-steel components, these sprinklers incorporate many
innovative and time-proven features for lasting, maintenance-free
operation.
Prior to installing the sprinkler, read through the recommended
installation and start-up procedures. Please observe all Warnings
and Cautions when installing and operating this equipment.
Features
• Full circle (360°) arc coverage
• Dual trajectory main nozzle adjustment – 25° standard or 15° low angle
• Two additional front nozzle positions
• Industry's largest precision nozzle selection
• All nozzles are color coded, debris tolerant and threaded in from the front
• Five electric and two hydraulic activation types
o Electric – Satellite systems – Standard 24 VAC solenoid; SPIKEGUARD 24VAC solenoid; Nickel plated
SPIKEGUARD 24VAC solenoid
o Electric – 2-wire systems – DC Latching solenoid; Integrated GDC module w/DC latching solenoid
o Hydraulic – Normally Open valve in head; Check-O-Matic (requires remote valve)
• Constant velocity drive and variable stator provide consistent rotation speeds
• Manual control at the sprinkler ON-OFF-AUTO (electric models only)
• Selectable/lockable pressure regulation settings; 50 psi (3,4 bar), 65 psi (4,5 bar), 80 psi (5,5 bar) or 100 psi (6,9 bar)
• Indestructable stainless steel valve seat and valve communication tube
• Body inlet rock screen serviceable from the top
• All internal components are serviceable from the top of the sprinkler
Specifications and Performance/Application Data
FLX34 Series
Radius: 52'–91' (15,8–27,7 m)
Flow Rate: 13–46.9 GPM (49,2–177,5 LPM)
Trajectory: Selectable 15° or 25°
Arc: Full Circle (360°)
Recommended Operating Pressure:
65–100 PSI (4,5–6,9 Bar)
Minimum Pressure: 40 PSI (2,8 Bar)
Maximum Pressure: 150 PSI (10,3 Bar)
Precipitation Rate:
Minimum: 0.39"/hr (9,9 mm/hr)
Maximum: 0.79"/hr (20,1 mm/hr)
Body Height: 10" (254 mm)
Pop-Up Height to Nozzle: 4 3/16" (106 mm)
Inlet Size: 1" (25 mm) NPT, BSP or ACME
Five electric activation types:
Standard Solenoid - 24 VAC, 50/60 Hz,
0.30 Amps Inrush, 0.20 Amps Holding
SPIKEGUARD Solenoid - 24 VAC, 50/60 Hz,
0.12 Amp Inrush, 0.10 Amp Holding
Nickel Plated SPIKEGUARD Solenoid - 24 VAC, 50/60 Hz,
0.12 Amp Inrush, 0.10 Amp Holding
DC Latching Solenoid - Momentary Low Voltage Pulse
Integrated GDC Module w/ DC Latching Solenoid -
Momentary Low Voltage Pulse
Manual Control (Electric VIH only): On-Off-Auto
Check-O-Matic Model checks up to 37' (11,2 m) of elevation
Seven Nozzle Variations
FLX34 & FLX54 Series Rotary Sprinklers
Installation and Service Instructions
FLX54 Series
Radius: 52'–99' (15,8–30,2 m)
Flow Rate: 13.2–61.8 GPM (50–234 LPM)
Trajectory: Selectable 15° or 25°
Arc: Full Circle (360°)
Recommended Operating Pressure:
65–100 PSI (4,5–6,9 Bar)
Minimum Pressure: 40 PSI (2,8 Bar)
Maximum Pressure: 150 PSI (10,3 Bar)
Precipitation Rate:
Minimum: 0.38"/hr (9,7 mm/hr)
Maximum: 0.77"/hr (19,6 mm/hr)
Body Height: 11" (289 mm)
Pop-Up Height to Nozzle: 4 3/16" (106 mm)
Inlet Size: 1.5" (40 mm) NPT, BSP or ACME
Five electric activation types:
Standard Solenoid - 24 VAC, 50/60 Hz,
0.30 Amps Inrush, 0.20 Amps Holding
SPIKEGUARD Solenoid - 24 VAC, 50/60 Hz,
0.12 Amp Inrush, 0.10 Amp Holding
Nickel Plated SPIKEGUARD Solenoid - 24 VAC, 50/60 Hz,
0.12 Amp Inrush, 0.10 Amp Holding
DC Latching Solenoid - Momentary Low Voltage Pulse
Integrated GDC Module w/ DC Latching Solenoid -
Momentary Low Voltage Pulse
Manual Control (Electric VIH only): On-Off-Auto
Check-O-Matic Model checks up to 37' (11,2 m) of elevation
Nine Nozzle Variations

Advertisement

loading

Summary of Contents for Toro FLX34 Series

  • Page 1 • Indestructable stainless steel valve seat and valve communication tube • Body inlet rock screen serviceable from the top • All internal components are serviceable from the top of the sprinkler Specifications and Performance/Application Data FLX34 Series FLX54 Series Radius: 52'–91' (15,8–27,7 m) Radius: 52'–99' (15,8–30,2 m) •...
  • Page 2 ⁄ " swing joint at flows over 25-GPM (95-LPM). Sprinkler radius data collected in Toro’s zero wind test facility per ASAE standard S398.1. Actual site conditions must be considered when selecting the appropriate nozzle. All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 PSI.
  • Page 3: Wire Splices

    Use Toro swing joints to connect the sprinklers to the lateral/main line pipe. Figure 1 Toro swing joints provide swivel joints that allow the sprinkler body to be easily positioned to finished grade and prevents pipe breakage by providing the flexibility to allow downward movement if the sprinkler is run over by heavy equipment.
  • Page 4: System Start-Up

    25' above controller elevation or 70' below controller elevation * - All hydraulic connections on Toro valves are 1/4" insert type. - Control line pressure must be equal to or greater than mainline pressure. - Control line pressure range is 40 to 150 PSI.
  • Page 5 Winterizing the irrigation system is required in freezing climates to prevent damage from water expansion when it freezes. Following are three key points for successfully winterizing the system, however, Toro provides a complete “Winterization and Pressurization Guide” (P/N 373-0849) that is available from your local Toro Distributor.
  • Page 6: Troubleshooting

    Pilot Valve Operation (Electric Models Only) The pilot valve controls the operation of the main valve located in the base of the sprinkler body. The main valve is operated by the release of water metered through the pilot valve when it is 100 PSI activated either manually at the sprinkler or by the irrigation system (7.0 kg/cm...
  • Page 7 Valve won’t close (Hydraulic) – Leak in control tubing • Isolate and repair – Pilot valve leak in controller • Confirm by observing constant dripping from discharge line of controller. Refer to Controller Service Manual – Valve cylinder misaligned with sprinkler body communication tube •...
  • Page 8: Servicing Procedures

    Refer to the Troubleshooting Procedure in this manual in the event of a malfunction. Some special tools are required for disassembly and/or maintenance of the sprinkler and are available from your Toro dealer. Servicing Sprinkler Mechanism WARNING! Never stand or lean over the sprinkler while the irrigation system is being filled, during manual or automatic operation or when performing sprinkler service procedures.
  • Page 9 Servicing Main Valve WARNING! If the valve snap ring is difficult to remove, residual water pressure may be remaining in the system. To prevent possible serious injury due to valve being ejected upward under pressure, confirm the following conditions exist prior to removing the snap ring and valve. A.
  • Page 10 Step 10 – Thoroughly clean and inspect all parts. Replace damaged parts as necessary and reassemble in reverse order. Note: For service part numbers, refer to www.toro.com and click Parts. Select the “Irrigation” category and search for “Pilot Valves”. Flushing Sprinklers WARNING! Never stand or lean over the sprinkler while the irrigation system is being filled, during manual or automatic operation or when performing sprinkler service procedures.
  • Page 11 NOTES:...
  • Page 12 NOTES: © 2015 • The Toro Company, Irrigation Division • www.toro.com Form Number 373-0858 Rev. A...

This manual is also suitable for:

Flx54 series