Panasonic ERV+DX Series Installation, Use And Maintenance Manual page 21

Energy recovery ventilation unit with dx coil
Hide thumbs Also See for ERV+DX Series:
Table of Contents

Advertisement

Available languages

Available languages

SECtIoN 1 - gENEral CharaCtErIStICS
1.1 Presentation of the manual
This manual describes the rules for the transportation, the installation, the use and the maintenance of the heat recovery. The user will find every-
thing that is normally useful to know for a correct and safe installation of the ERV+DX unit.
The non-observance of what is described in this handbook and an inadequate installation of the ERV+DX unit may cause the cancellation of the
guarantee that the Manufacturer/Distributor Company grants on the same one. The Manufacturer/distributor Company, moreover, does not
answer to possible direct and/or indirect damages due to wrong installation carried out by inexpert and/or non-authorised staff. At the moment of
the purchase, check that the machine is integral and complete. Claims will have to be produced within 8 days from the reception of the goods.
1.2 general characteristics
• Galvanized steel self-supporting panels, internally and externally insulated
• Counterflow air-to-air heat recovery device, made of plane sheets of special paper with special sealing to keep airflows separate and only
permeable to water vapor. total heat exchange with temperature efficiency up to 77% and enthalpy efficiency up to 63%, also at high level
during summer season
• G4 efficiency class filters with synthetic cleanable media, both on fresh air and return air intake
• Removable side panel to access filters and heat recovery in the event of scheduled maintenance
• Motorised heat recovery by-pass device automatically controlled by unit control to use fresh air free-cooling when convenient
• Low consumption, high efficiency & low noise direct driven fans with 3-speed EC motors
• Supply section complete with DX coil (R410A) fitted with solenoid control valve, freon filter, contact temperature sensors on liquid and gas
line, NTC sensors upstream and downstream airflow
• Purifying system Bioxigen
®
plied air
• Built-in electric box equipped with PCB to control internal fan speed and to interconnect outdoor/indoor units
• Duct connection by circular plastic collars
1.3 Erv+DX series technical data
moDEl Erv+DX
Nominal airflow rate
Nominal E.S.P.
1,5 m sound pressure level
Power supply
Max current
Max power input
hEat rECovEry
Winter mode
(1)
Temperature efficiency
Enthalpy efficiency
Saved power
Summer mode
(2)
Temperature efficiency
Enthalpy efficiency
Saved power
DX CoIl
heating mode
Total capacity
Off temperature
Off R.H.
Cooling mode
Total capacity
Sensible capacity
Off temperature
Off R.H.
(1) Nominal winter conditions:
outside air: -5°C (-10°C) DB, RH 80%
ambient air: 20°C DB, RH 50%
(2) Nominal summer conditions:
outside air: 32°C DB, RH 50%
ambient air: 26°C DB, RH 50%
, switched on at fans running, able to do an efficient antibacterial treatment, ensuring a perfect healthiness of sup-
High speed
Med speed
Low speed
High speed
Med speed
Low speed
High speed
Med speed
Low speed
Installation, Use and Maintenance Manual - ERV+DX series
PaW-500zDX2 PaW-800zDX2 PaW-01KzDX2
500
m
/h
500
3
360
85
Pa
45
21
33
dB (A)
31
27
V/ph/Hz
230/1/50
A
1,1
W
135
76,5 (76,5)
%
62,3 (64,1)
59 (60,8)
W
4,3 (4,8)
6,5 (7,3)
62,5
%
60
W
1,7
kW
2,9 (3,1)
4,0 (4,3)
°C
30,1 (29,2)
27,5 (26,5)
%
16 (15)
kW
3,0
kW
2,0
°C
16,5
%
86
800
1000
800
780
625
650
117
104
68
69
18
17
38
39
36
37
32
33
2,3
2,5
300
310
73 (73)
73,5 (73,5)
59,5 (61,2)
8,2 (9,0)
59
59,5
57
57,5
2,5
3,2
4,6 (5,0)
26,3 (25,3)
18 (17)
19 (18)
4,0
4,5
2,8
3,3
17,9
18,6
82
81
page 21