– As a colored background around the device name in the project tree.
– As a colored MIL in the "Error Info" window.
– As a colored dot in the error memory at the bottom.
The colors and their meaning:
– Grey: No connection with the device.
– Green: Matching configuration and firmware between device and project.
– Orange: A different configuration between device and project.
– Red: A different firmware between device and project.
– Purple: Device is bricked, too many resets. Reflash the device, reconsider last changes.
– Colored background with orange stripes: Matching configuration with stored (inact-
ive) errors in the device.
– Blinking colored background with orange stripes: Matching configuration with active
errors in the device.
– Black MIL: No errors.
– Orange MIL: Inactive Errors (Error entries existing, but no longer active).
– Blinking MIL (orange/black): Active Errors.
For further information, see chapter Error Memory Properties [} 103].

8.7 Assign the Mounting Location

At delivery the default role of the devices is set. There is no need to change this, until you
want more than one device of this kind. Up to eight C 80 can be used additionally in one
network for I/O expansion and or Multilogging, the mounting location is used for determ-
ination between the different C 80.
In case of M60/MSI60, at delivery no mounting location is set. This is signaled by an or-
ange 'RUN' LED on the device. Therefore one must first assign a mounting location to the
C 80 before it can be used in the project. The mounting location is permanently saved in
the C 80. If necessary, you can reassign a different mounting location at any time follow-
ing the same procedure.