Haier HZY-40Z User Manual

Haier HZY-40Z User Manual

Mobile transport cooler

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Haier HZY-40Z

  • Page 2: Table Of Contents

    Content Safety Precautions ..........1 Application guidelines ..........4 Product Features .............5 Installation ...............6 Components Display panel ........7 ● Application Method ..........9 Debug and Use............10 Alarm ..............12 Clean and disinfection ..........13 Maintenance routine ..........15 FAQ ................16 Circuit diagram ............17 Specifi cation ............18...
  • Page 3: Safety Precautions

    Safety Precautions Dear users: Thanks for your choice of Haier Mobile transport cooler; please make sure you have carefully read and observed the contents with following signs in the manual, for better understanding of this manual and better use of this product, so as to prevent personal injuries and refrigerator damage.
  • Page 4 Please use the power outlet with ground wire in case of electric shock. If the power outlet is not grounded, be sure to install the ground wire by professional technicians. When using the battery to supply power, pay attention to the positive and negative electrodes of the battery, do not reverse the connection.
  • Page 5 Do not put water containers or heavy objects on the transport cooler, if the items fall, the water that may cause injury to personnel and the outfl ow will reduce the insulation caused by leakage or electric shock. No landing shall be made to the transport cooler through gas pipes, power supply pipes, telephone lines or lightning rods.
  • Page 6: Application Guidelines

    Application guidelines • Structure and Composition: The product consists of box, refrigeration system, control system (including alarm system) and basket. • The temperature display value of the transport cooler shows the value at the temperature sensor probe in the box. Although the temperature displayed is sometimes somewhat different from the actual value of the central part, it gradually approaching the true temperature.
  • Page 7: Product Features

    Product Features Expected purpose This product is suitable for pharmacy, pharmaceutical factory, epidemic prevention station, hospital, health center and other medical institutions to temporarily store or transport drugs, reagents, vaccines, biological products and other temperature sensitive items. No absolute contraindication. The transport cooler can’t be used beyond the expected performance.
  • Page 8: Installation

    Installation Unpacking and handling • Use appropriate tools, such as scissors or wallpaper knife, cut the packing tape, remove the screws on the outer packing box with a screwdriver, then remove the packing; • Check the accessories. Do not scratch the appearance of the equipment. Installation environment •...
  • Page 9: Components Display Panel

    Components Display panel ● Components Display panel Door Handle Lock catch Main body Aviation plug Castor...
  • Page 10 Display panel Power Alarm Cooling Battery Back Heating Network LED indicators: Indicative contents Power Green, Lighting: Normal; Flashing: Abnormal(overvoltage or under-voltage) Cooling Green,Lighting: compressor is working Alarm Red,Flashing: Alarm occurs Heating Yellow,lighting: Heater is working Battery Green, fl ashing: Battery power is less than 20% Network Green,Lighting: Normal;...
  • Page 11: Application Method

    Application Method User setting Press“Set”button for 5s,LED displays “TS”.Press “+”or“-”LED displays: ALH→ALL→dA→Uc→Uct→TS. Press“Set”button,LED displays the value of the parameter, press“+”or“-”to adjust the value,After choose your needed value.Press“set”button to confi rm. Press“Back”button to exit. Parameter High temp. Low temp. Defi nition Set value Time for UVC Alarm...
  • Page 12: Debug And Use

    Debug and Use Preparation before use • Working Temperature:0℃ ~35℃; Power on • According to the actual power supply situation, select the appropriate power cord, random with AC power cord, battery power supply cable, Car-charger power supply cable. • Connect the main power supply. •...
  • Page 13 First electric connection Please follow the regulations below for the fi rst start and the continuous operation: Please connect the cooler to the power supply of appropriate specifi cation when the storage box is empty. Factory default setting value of cooler is 4℃ , if you need to adjust, please refer to the instructions to adjust accordingly.
  • Page 14: Alarm

    Alarm Alarm and alarm code Alarm type Alarm description Alarm code Alarm indicator High temperature Alarm Inner temperature >alarm value Buzzer and light Low temperature Alarm Inner temperature < alarm value Buzzer and light Door open alarm Door opens for more than 30S Buzzer and light Control sensor Buzzer and light...
  • Page 15: Clean And Disinfection

    • In doubt about the compatibility of disinfectant or cleaning agent with the material contained in the equipment parts or equipment, please consult the Haier or Haier designated agency. • Cleaning outer surfaces a) Use warm water and detergent solution to remove dirt residues and sediment;...
  • Page 16 c) fi nal disinfection Wipe/spray disinfectant on the removed shelf and air duct board and make it fully sterilized in accordance with the requirements of the disinfectant manufacturer; Dry shelf and air duct surface with clean cloth; Reinstall shelves and air duct panels; Alcohol disinfection! a) Disinfectant with alcohol content of more than 10%, combine with air to form fl...
  • Page 17: Maintenance Routine

    Haier engineer; • In the course of routine maintenance and maintenance, only Haier or Haier designated agencies can inspect or provide spare parts for the maintenance of transport cooler;...
  • Page 18: Faq

    This chapter is to give answers in respect of potential fault phenomenon as well as respective solutions. If your question is still unresolved after operation, please contact Haier after-sales service. Do not maintain and dismantle the transport cooler by yourself!
  • Page 19: Circuit Diagram

    Circuit diagram...
  • Page 20: Specifi Cation

    Specifi cation Specifi cation Name Parameters Model HZY-40Z Exterior Dimensions 800×550×505 (W*D*H) (mm) Interior Dimensions 338×348×285 (W*D*H) (mm) Insulation CFC-Free foamed-in-place urethane Cooling type Compressor Exterior / Interior HDPE Temperature Control Microprocessor controlled Net Weight (Kg) Temperature Range (℃ )
  • Page 21 Packing list Name HZY-40Z basket Power cord(AC、DC) User manual Plastic bag castor...

Table of Contents