Cc-Link Compatible Module Specifications - Yamaha RCX Series User Manual

Network board. cc-link compatible module
Hide thumbs Also See for RCX Series:
Table of Contents

Advertisement

5. CC-Link compatible module specifications

5. CC-Link compatible module specifications

The CC-Link compatible module with the label is compatible with CC-Link Ver. 1.10.
Limits on the station-to-station cable length, etc., can be eased by using the Ver. 1.10
compatible CC-Link cable. Refer to the master station PLC instruction manual compatible
with Ver. 1.10.
Specification item
Target controller
Remote station type
Number of occupied
stations
Chapter
Station No. setting
5
Communication speed
setting
Number of CC-Link
input/output points *1)
Monitor LED
*1) Controller's I/O update intervals are 10ms at shortest, but actual I/O update intervals change
depending on the update time for the master station.
c
CAUTION
• For the names and description of remote input/output signals and remote
registers, refer to the tables shown in "1. Profi le" and "2. Details of remote input/
output signals" in this chapter.
• The specifi cations and appearance are subject to change without prior notice.
5-20
RCX series controller
Remote device station
Fixed to four stations
1 to 61 (rotary switch)
10M / 5M / 2.5M / 625K / 156Kbps (rotary switch)
Dedicated input
Remote
General-purpose input
input/
Dedicated output
output
General-purpose output : 96 points
Dedicated input
General-purpose input
Remote
register
Dedicated output
General-purpose output : 14 words
RUN, ERRL, SD, RD
CC-Link compatible module
: 16 points
(13 points are currently used for RCX221/222.)
(12 points are currently used for RCX40/141/142.)
: 96 points
: 16 points
(12 points are currently used for RCX221/222.)
(11 points are currently used for RCX40/141/142.)
: 2 words
: 14 words
: 2 words