Settings And Adjustment When Peripheral Equipment Is Connected; Time Code Setting - Sony DNW-A100 Maintenance Manual

Digital video hybrid recorder
Hide thumbs Also See for DNW-A100:
Table of Contents

Advertisement

1-15. Settings and Adjustment when Peripheral Equipment is Connected

1-15. Settings and Adjustment when Peripheral Equipment is Connected
Refer to "1-15-4" for setting when connecting the extended hard disk.

1-15-1. Time Code Setting

When Editing with a Connected Editor (BVE-2000 etc.) Capable of the 1st Edit
TC GENERATOR switches on upper control panel
INT / EXT
RESET / REGEN
FREE RUN / REC RUN
The standard constant values of a connected editor
The standard constants of each model are shown as follows.
Model name
1
2
DNW-A100
B0
41
DNW-A100P
B1
41
DNW-A50
B0
45
DNW-A50P
B1
45
DNW-A45
B0
45
DNW-A45P
B1
45
n
1. Set the data of No.8 of the VTR CONSTANT 1 to "0A" for the following editors.
. BVE-900 ROM version: less than or equal 1.08
. BVE-600 ROM version: less than or equal 1.01
2. In case of remote-controlling this unit by the editor, set the setup menu ITEM No.401: FUNCTION
MODE AFTER CUE-UP to "STOP".
When Editing with Direct Machine-to-Machine
n
The setup menu ITEM-601: REGEN CONTROL MODE setting data must be set to "AS&IN".
TC GENERATOR switches on upper control panel
INT / EXT
RESET / REGEN
FREE RUN / REC RUN
1-28
8 INT
8 PRESET
8 FREE RUN
VTR CONSTANT1
Data No.
3
4
5
6
7
00
96
07
07
03
00
96
07
07
03
00
96
07
07
03
00
96
07
07
03
00
96
07
07
03
00
96
07
07
03
8 INT
8 PRESET
8 REC RUN
VTR CONSTANT2
Data No.
8
1
2
3
4
8A
0A
07
FB
00
8A
0A
07
FB
00
8A
0A
07
FB
00
8A
0A
07
FB
00
8A
0A
07
FB
00
8A
0A
07
FB
00
The values are shown in hexadecimal notation.
5
6
7
8
81
3D
FF
4B
81
3D
FF
4B
81
3D
FF
4B
81
3D
FF
4B
81
3D
FF
4B
81
3D
FF
4B
DNW-A100/A50/A45
DNW-A100P/A50P/A45P