DIAGNOSTIC STATUS CODES
TRANSISTOR PUMP CONTROL
Section 4.8 Pump Control Codes
PUMP
DESCRIPTION OF STATUS
STATUS CODE
"Card Type" selection is invalid.
-117
MEMORY R CALL
E
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Pump
Invalid card type selection.
Controller
· Review function 17 in the Handset
Instruction sheets. Adjust and set
card type value as instructed by OEM
service manual.
PUMP
DESCRIPTION OF STATUS
STATUS CODE
Control logic card power supply is less
-127
than 10 VDC.
MEMORY RE ALL
C
YES
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Pump
Controller
Discharged Battery
· Check battery to insure proper state
of charge.
Loose connection at P1.
· Insure that the wire connection at P1
is tight.
CORRECTIVE ACTIONS
CORRECTIVE ACTIONS
CAUSE OF STATUS INDICATION
This status code will be displayed when the card type
selection value is set to an invalid number.
TROUBLE-SHOOTING DIAGRAM
NO
GRAPHIC
FOR THIS
STATUS CODE
CAUSE OF STATUS INDICATION
This status code is displayed when the logic card
power supply is less than 10 volts.
TROUBLE-SHOOTING DIAGRAM
FU3
FU2
LINE
FU1
+
-
POWER CONNECTIONS
Page 44
KEY SWITCH
P1 P2
POS
A1
NEG
A2
October 2002