Commissioning Of The Appliance; Maintenance (Only For Approved Specialists); Information For Users; Cleaning - Bosch TRONIC 1000 T Installation And Operating Instructions Manual

Dhw tank
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 150

Commissioning of the appliance

If the power cable is damaged, it must be replaced with an
original spare part.
▶ Disconnect the power cable from the socket.
▶ Loosen the cover flap screws.
▶ Release all of the terminals of the power cable.
▶ Remove the supply cable and replace it with a new one.
▶ Re-attach all of the connections.
▶ Tighten the cover flap connections.
▶ Connect the power cable to the socket.
▶ Check that it is working properly.
7
Commissioning of the appliance
▶ Check for correct installation of the DHW tank.
▶ Open the water valves.
▶ Open all of the hot water taps and completely vent the water
lines.
▶ Check the tightness of all connections, and fill up the tank.
▶ Connect the DHW tank to the power supply.
▶ Instruct the customer in the function and operation of this
DHW tank.
8
Maintenance (only for approved
specialists)
Inspection, maintenance and repairs,
▶ Inspection, maintenance and repairs must only be carried
out by competent and authorised persons.
▶ Use only original spare parts from the manufacturer. The
manufacturer will assume no responsibility for damage
caused by spare parts not supplied by the manufacturer.
Customer recommendation: Maintenance checks.
▶ The appliance should be serviced annually by a competent
authorised technician in order to maintain the economy,
safety and reliability of the appliance.
8.1

Information for users

8.1.1 Cleaning

▶ Do not use abrasive, caustic or solvent-containing cleaning
agents.
▶ Use a soft cloth to clean the outside of the appliance.
162

8.1.2 Checking the pressure relief valve

▶ Check whether water leaks from the pressure relief valve
vent pipe during heating.
▶ Never obstruct the vent pipe of the pressure relief valve.

8.1.3 Pressure relief valve

▶ Open the pressure relief valve manually at least once a
month (Fig. 8).
CAUTION
Risk of personal or material damage!
▶ Ensure that the water discharged by the pressure relief
valve does not pose a risk to people or property.

8.1.4 Maintenance and Repair

▶ The customer is liable for ensuring regular maintenance
and testing by customer service or an approved contractor.
8.2

Periodic maintenance works

CAUTION
Risk of personal or material damage!
Before commencing any maintenance work:
▶ Switch off the electric supply.
▶ Close the water shut-off valve.
▶ Only use original spare parts.
▶ Order spare parts from the spare parts catalogue for this
appliance.
▶ During maintenance work, replace removed joints with new
ones.

8.2.1 Functional check

▶ Check that all components are functioning correctly.
CAUTION
Risk of damage to property!
Risk of damage to the enamel coating.
▶ Never clean the enamelled interior of the appliance with
descaling agents. No additional products are necessary to
protect the enamel coating.
8.3

Protection anode

The appliance is protected against corrosion by a magnesium
anode in the tank.
Tronic 1000 T | Tronic 2000 T – 6721831855 (2021/03)

Advertisement

Table of Contents
loading

Table of Contents