Fig. 9-2: Connection for 24 V power supply
Pin
Function
1
+24 V supply voltage
2
0 V supply voltage
3
n.c.
Use a 24 V industrial power supply unit acc. to DIN EN 60742, classification VDE
0551, for example "VAP01.1H-W23-024-010-NN" (part number R911171065) for
the voltage supply.

9.3 Battery connection

The battery devices can be accessed directly in built-in devices. In housing devi-
ces, the cover of the cable entry has to be opened.

9.4 USB interfaces

At the devices, there are two USB interfaces at the connector panel (XF30 and
XF31). At the housing devices, there is an additional USB 2.0 interface at the
front panel.

9.4.1 Operating USB ports at operator display

Interference-free USB connections are only possible up to the fol-
lowing maximum cable lengths:
USB 2.0: 5 m
USB 3.0: 3 m
Connect only USB devices that meet the USB 2.0/3.0 specification.
The cables of the connected USB devices have to comply with the
USB 2.0/3.0 specifications.

9.4.2 USB 2.0 interface XF30

One USB interface acc. to the USB 2.0 specification is provided at the devices.
XD1
+24 VDC
1 2 3
0 VDC
n.c.
XD1
Potential-free
1
supply unit
2
3