Download Print this page
Sealey DUAL FUSION AB2200Q Instructions Manual

Sealey DUAL FUSION AB2200Q Instructions Manual

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE
PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
Electrical
Hot
Hazard
Surface
1.1.
ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and
any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of
appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also
recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are
plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual
Current Device by contacting your Sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
1.1.1. The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.
and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check all
connections to ensure that none is loose.
1.1.6. Important: Ensure that the voltage marked on the appliance matches the power supply
to be used and that the plug is fitted with the correct fuse - see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty
item repaired or replaced by a qualified electrician. When a BS 1363/A UK 3 pin plug is
damaged, cut the cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation
extends beyond the cable restraint and that the restraint is tight.
Double insulated products, which are always marked with this symbol
rewire, connect the wires as indicated above.
DO NOT connect either wire to the earth terminal.
1.1.10. Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure
that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket
with your electrician.
1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance
plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use
of 2.5mm² section cable.
1.2.
GENERAL SAFETY
DANGER! Risk of carbon monoxide poisoning. Failure to provide proper ventilation could result in serious illness or death.
Check that the heater is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
 Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
 Only use paraffin, diesel or kerosene to fuel this heater, in accordance with instructions contained in this manual.
 Locate heater on a level and stable surface.
WARNING! Only use heater in well ventilated areas. Ensure continuous ventilation is provided to the heater operating area via windows
and doors etc. If people are not required to be present in the heated area, the volume of air to be heated (mtr³)/heat output (kW) ratio must
be at least 10:1 and people must be advised not to remain in the heated area for prolonged periods. If people are required to be present in
the heated area, the volume of air to be heated (mtr³)/heat output (kW) ratio must be at least 30:1. Ventilation must be to the outside of the
premises in which the heater is to be operated. Minimum Ventilation Opening Needed: AB2200Q - 5990cm² (6.5ft²). The
volume concentration of oxygen (O
WARNING! DO NOT use the heater near flammable material, liquids, solids, gases or compressed gas cylinders etc.
 DO NOT stand or place any object less than 3m from the heater output and keep the heater a minimum of 2m from any walls or objects.
 DO NOT use the heater in closed rooms, living areas, basements or below ground level.
© Jack Sealey Limited
INSTRUCTIONS FOR:
DUAL FUSION® PARAFFIN/KEROSENE &
DIESEL HEATER 170,000/220,000Btu/hr
WITH WHEELS
MODEL No:
Unexpected
Start Up
) in the heated room, must always remain above 17%.
²
Original Language Version
AB2200Q
, are fitted with live (brown) and neutral (blue) wires only. To
RECOMMENDED
FUSE RATING: 5AMP
AB2200Q
Issue:1 - 28/07/14

Advertisement

loading

Summary of Contents for Sealey DUAL FUSION AB2200Q

  • Page 1 AB2200Q MODEL No: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Specification

    Remove the heater and all the packaging from the carton. Note: make sure the axle is removed from the side of the polystyrene packaging. 4.2. Tools Required: cross head screwdriver, 8mm open ended spanner, 19mm open ended spanner. 4.3. Contents Fig.2 Original Language Version © Jack Sealey Limited AB2200Q Issue:1 - 28/07/14...
  • Page 3: Operation

    5.3.1. To stop the heater, move the power switch to the "Off" position and unplug the mains cable. 5.3.2. To restart the heater wait 10 seconds and follow 5.2. "Starting the Heater" steps. Fig.4 Fig.5 Fig.6 Original Language Version © Jack Sealey Limited AB2200Q Issue:1 - 28/07/14...
  • Page 4: Maintenance

    6.1.4. To replace the drain plug; push the drain head fully into the drain hole and secure by pushing the seal cap fully into the head hole. (See fig.6). 6.2. Service 6.2.1. DO NOT tamper with the unit. Return to a Sealey service agent. 6.3. Maintenance Schedule 6.3.1. Fuel/Fuel Tank: flush tank every 200 hours of operation or as needed, (refer to section 6.1). DO NOT flush with water, use fresh kerosene only.
  • Page 5: Wiring Diagram

    7. WIRING DIAGRAM Original Language Version © Jack Sealey Limited AB2200Q Issue:1 - 28/07/14...
  • Page 6: Troubleshooting

    8. TROUBLESHOOTING Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500. Environmental Protection Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sort- ed, taken to a recycling centre and disposed of in a manner which is compatible with the environment.