Miele CVA 6805 Operating And Installation Instructions page 81

Built-in coffee machine
Table of Contents

Advertisement

^ Push the tubes back onto the angled
connector and replace this in the
machine.
^ Re-insert the air intake tube into
opening c.
Step 3: Maintaining the milk
valve and cleaning the milk
pipework in the central spout
^ Touch "Main menu" or the # sensor.
^ Touch "Maintenance" y.
^ Touch "Clean the central spout".
The central spout will move into the
maintenance position.
Important. You must remove the
cleaning brush before confirming
"Quit maintenance position" with
"OK". Otherwise the coffee machine
will be damaged.
Cleaning blockages from the milk pipework
^ Insert the brush in the milk valve.
Move the brush back and forth.
^ Remove and dismantle the
dispensing unit as described in
"Cleaning and care - Central spout".
^ Rinse all parts carefully under
running water.
Use the cleaning brush to clean all
parts carefully. In order to avoid
pushing out the silicone parts, do
not use a needle or similar
implement.
^ Reassemble the central unit and
replace it in the central spout.
^ Replace the cover.
^ Touch "OK".
The milk valve will move into the correct
position and the milk pipework will be
rinsed through.