6. ELECTRICAL DATA

6-1. Electrical Characteristics

Indoor Unit
SAP – KR184GJ
Outdoor Unit
SAP – CR184G
Performance at
Rating Conditions
Full Load Conditions Running Amps.
Rating Conditions
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Indoor Unit
SAP – KR224GJ
Outdoor Unit
SAP – CR224G
Performance at
Rating Conditions
Full Load Conditions Running Amps.
Rating Conditions
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Indoor Unit
Running Amps.
A
Power Input
kW
A
Power Input
kW
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
Running Amps.
A
Power Input
kW
A
Power Input
kW
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Outdoor Air Temperature 43°C D.B.
Fan Motor
Fan Motor
240V Single phase 50Hz
0.31
0.54
0.035
0.122
0.31
0.54
0.035
0.122
Fan Motor
Fan Motor
240V Single phase 50Hz
0.37
0.54
0.041
0.122
0.37
0.54
0.041
0.122
20
Outdoor Unit
Compressor
6.05
1.473
8.65
1.993
Outdoor Unit
Compressor
6.25
1.443
8.65
1.993
Complete Unit
6.90
1.630
9.50
2.150
Complete Unit
9.6
2.280
12.5
2.840