Air-Conditioners For Building Application
INDOOR UNIT
PKFY-P·VAM-E / PKFY-P·VGM-E
PMFY-P·VBM-E / PCFY-P·VGM-E
PLFY-P·VAM-E
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme
gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du
climatiseur.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de
airconditioner gebruikt.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado
para garantizar un uso seguro y correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro
della stessa.
E°XEIPI¢IO O¢H°IøN XPH™Eø™
°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ¯Ú‹Ûˆ˜ ÚÈÓ ı¤ÛÂÙ ÛÂ
ÏÂÈÙÔ˘ÚÁ›· ÙË ÌÔÓ¿‰· ÎÏÈÌ·ÙÈÛÌÔ‡.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a
unidade de ar condicionado.
Iflletme Elkitab›
Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› iflletmeden önce bu
elkitab›n› dikkatle okuyunuz.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Для обеспечения правильного и безопасного использования следует ознакомиться с инструкциями,
указанными в данном руководстве по эксплуатации, тщательным образом до того, как приступать к
использованию кондиционера.
Back to Index
FOR USER
FÜR BENUTZER
POUR L'UTILISATEUR
VOOR DE GEBRUIKER
PARA EL USUARIO
PER L'UTENTE
°π∞ ∆√¡ Ã∏™∆∏
PARA O UTILIZADOR
KULLANICI ‹Ç‹N
ДЛЯ ПОЛЬЗОВАТЕЛЯ
(
)
English
Deutsch
Français
Nederlands
Español
Italiano
∂ÏÏËÓÈο
Português
Türkçe
Русский

Advertisement

loading

Summary of Contents for Mitsubishi Electric PKFY-P VAM-E

  • Page 1 Air-Conditioners For Building Application INDOOR UNIT PKFY-P·VAM-E / PKFY-P·VGM-E PMFY-P·VBM-E / PCFY-P·VGM-E PLFY-P·VAM-E Back to Index OPERATION MANUAL FOR USER English For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH FÜR BENUTZER Deutsch Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
  • Page 2: Table Of Contents

    Contents 1. Safety Precautions ..................................2 2. Operation ..................................... 3 3. Care and cleaning ..................................5 4. Troubleshooting ................................... 6 5. Specifications ....................................7 1. Safety Precautions s Before installing the unit, make sure you read all the “Safety precautions”. s The “Safety precautions”...
  • Page 3: Operation

    2. Operation 1[Time-setting] Button Used to set the current time, starting time, and ending time. 2[Timer/continuous] Button Used to switch between continuous operation and timer operation. 3[Selecting operation] Button CENTRALLY CONTROLLED 1Hr. ON OFF ˚C CLOCK Used to switch between cooling, dry, air blowing, and heating. CHECK FILTER CHECK MODE...
  • Page 4 2. Operation 2.3. Selecting a temperature TEMP. s s s s s To decrease the room temperature: 1 Press button to set the desired temperature. A The selected temperature is displayed. • Each time you press the button, the temperature value decreases by ˚C 1 °C.
  • Page 5: Care And Cleaning

    2. Operation I PCFY Series I PCFY Series • Shut down the operation in progress, and then move the vertical air vane horizontally. The vanes at both ends do not move. • Adjust the horizontal airflow vanes to the desired angle (within 45° to the right and left).
  • Page 6: Troubleshooting

    3. Care and cleaning I PKFY-P·VAM Series I PKFY-P·VAM Series I PKFY-P·VGM Series I PKFY-P·VGM Series 1 Pull both the bottom corners of the intake grille to open the grille, then lift the filter. I PMFY-P·VBM Series I PMFY-P·VBM Series 1 Pressing the PUSH button on the outer side of the intake grille causes the intake grille to open.
  • Page 7: Specifications

    4. Troubleshooting The following symptoms are not air conditioner failures: • The air blown out from the air conditioner can sometimes give off odors. This is due to cigarette smoke contained in the air of the room, the smell of cosmetics, the walls, furniture, etc., absorbed in the air conditioner.
  • Page 8 This product is designed and intended for use in the residential, commercial and light-industrial environment. • Low Voltage Directive 73/23/ EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following 336/ EEC EU regulations: Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

This manual is also suitable for:

Pkfy-p vgm-ePmfy-p vbm-ePcfy-p vgm-ePlfy-p vam-e