Frigidaire FEQBB30DS0 Installation Instructions Manual
Frigidaire FEQBB30DS0 Installation Instructions Manual

Frigidaire FEQBB30DS0 Installation Instructions Manual

Gas & electric dryer
Hide thumbs Also See for FEQBB30DS0:

Advertisement

Frigidaire
Electronic
Installation
Instructions
Gas &
Electric
Dryer
Before beginning installation, carefully read these instructions. This will simplify the installation and ensure
the dryer is installed correctly and safely. Leave these instructions near the Dryer after installation for future
reference.
NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Electrical Code, ANSI/NFPA 70.
NOTE: The gas service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Fuel Gas Code ANSI Z223.1.
NOTE: The Dryer is designed under ANSI Z 21.5.1 or ANSI/UL 2158 - CAN/CSA C22.2 (latest editions) for HOME
USE only. This Dryer is not recommended for commercial applications such as restaurants or beauty salons, etc.
www.frigidaire.com
Pre-Installation Requirements................................ 2
Electrical Requirements........................................ 2
Ventilation System Requirements..................................... 3-4
Exhaust System Requirements............................................. 4
Gas Supply Requirements..................................................... 4
Location of Your Dryer.......................................................... 5
Mobile Home Installation..................................................... 6
Rough-In Dimensions........................................................ 6-7
Unpacking........................................................... 7
Reversing Door Swing........................................... 7
Electrical Installation............................................. 8
Grounding Requirements....................................... 8
Electrical Connections-4-wire.............................. 9
Gas Connection................................................... 10
General Installation.............................................. 10
Replacement Parts.............................................. 10

Save These Instructions

1
P/N 134306200A (0312)

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire FEQBB30DS0

  • Page 1: Table Of Contents

    Leave these instructions near the Dryer after installation for future reference. NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70.
  • Page 2: Pre-Installation Requirements

    POWER SUPPLY - 3 wire, 120 volt single phase, 60 Hz, Alternating Current. POWER SUPPLY CORD - The dryer is equipped with a 120 volt 3-wire power cord. NOTE: Do not under...
  • Page 3: Ventilation System Requirements

    If the dryer is not exhausted outdoors, some fine lint will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard. The dryer exhaust system MUST be exhausted to the outside of the...
  • Page 4: Exhaust System Requirements

    All dryers shipped from the factory are set up for rear exhausting. However, on electric dryers, exhausting can be to the right or left side of the cabinet or the bottom of the dryer. On gas dryers, exhausting can be to the right side of the cabinet or the bottom of the dryer.
  • Page 5: Location Of Your Dryer

    Gas dryer. 3. Your dryer needs the space around it for proper ventilation. DO NOT install your dryer in a closet with a solid door. 4. A minimum of 120 square inches (774.2 square cm) of opening, equally divided at the top and bottom of the door, is required.
  • Page 6: Mobile Home Installation

    Metal ducting must be 4 inches (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred. 2. If dryer is exhausted through the floor and area beneath the mobile home is enclosed, the exhaust system MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure.
  • Page 7: Rough-In Dimensions

    (68.6 cm) SIDE VIEW 1. Using the four shipping carton corner posts (two on each side), carefully lay the dryer on its left side and remove the foam shipping base. 2. Return the dryer to an upright position. (110.7 cm) 36"...
  • Page 8: Electrical Installation

    A U.L. approved strain relief must be installed onto power cord. If the strain relief is not attached, the cord can be pulled out of the dryer and can be cut by any movement of the cord, resulting in electrical shock.
  • Page 9: Electrical Connections

    5. Attach the green power cord ground wire to the cabinet with the green ground screw. 6. Attach the white (neutral) power cord conductor from the power cord and the green ground wire from the dryer harness to the silver-colored center terminal on the terminal block. Tighten the screw securely.
  • Page 10: Gas Connection

    1. Connect the exhaust duct to outside exhaust system (see pages 3 and 4). Use duct tape to seal all joints. 2. With the dryer in its final position, adjust one or more of the legs until the dryer is resting solid on all four legs.