Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. SAFETY
WARNING! Ensure health & safety, local authority, and general workshop practice regulations are adhered to when using this
equipment.
WARNING! Disconnect from air supply before changing accessories or servicing.
Maintain the needle scaler in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts may
9
be dangerous and will invalidate the warranty.
WARNING! Check correct air pressure is maintained and not exceeded. We recommend 90psi.
Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use and ensure that all connections are
9
secure.
Only use needles which are specifically designed for use with a needle scaler.
9
Wear approved safety eye/face shield, ear defenders, and hand protection.
9
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
9
Keep children and non-essential persons away from the working area.
9
DO NOT use the needle scaler for a task it is not designed to perform.
8
WARNING! DO NOT use needle scaler if damaged or thought to be faulty. (Contact Sealey service agent).
DO NOT use needle scaler unless you have been instructed in its use by a qualified person.
8
DO NOT carry the needle scaler by the air hose, or yank the hose from the air supply.
8
DO NOT operate needle scaler if you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT carry needle scaler with your hand on the power trigger in order to avoid unintentional starting.
8
DO NOT direct air from the air hose at yourself or others.
8
When not in use disconnect from air supply and store in a safe, dry, childproof location.
9
2. INTRODUCTION
Straight type air hammer supplied with interchangeable needle and chisel heads. Suitable for cleaning heavy paint and rust scale from metal
surfaces. Palm control trigger mechanism. Replacement needle set and chisel available.
3. SPECIFICATION
Stroke: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32mm
Free speed: . . . . . . . . . . . . . . . . . . . . . . 4800bpm
Air consumption:. . . . . . . . . . . . . . . . . . . . . . . 3cfm
Operating pressure: . . . . . . . . . . . . . . . . . . . 90psi
Air inlet size: . . . . . . . . . . . . . . . . . . . . . . . 1/4"BSP
Noise Power: . . . . . . . . . . . . . . . . . . . . . 105dB(A)
Noise Pressure: . . . . . . . . . . . . . . . . . . . . 94dB(A)
Vibration Emission Value:. . . . . . . . . . . . . 8.56m/s²
Uncertainty Emission Value:. . . . . . . . . . . 1.34m/s²
Replacement Needle Set (12pc): . . . . . . . SA51/16
Replacement Chisel: . . . . . . . . . . . . . . . . SA52/15
4. PREPARATION
4.1.
AIR SUPPLY
4.1.1.
Ensure tool valve (or trigger) is in the "off" position before connecting to the air supply.
4.1.2.
You will require an air pressure of 90psi, and an air flow according to specification.
WARNING! Ensure the air supply is clean and does not exceed 90psi while operating the tool. Too high an air pressure and unclean air
will shorten the product life due to excessive wear, and may be dangerous causing damage and/or personal injury.
4.1.3.
Drain the air tank daily. Water in the air line will damage the tool.
4.1.4.
Clean air inlet filter weekly. Recommended hook-up procedure is shown in fig.1.
4.1.5.
Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The minimum hose diameter should be
1/4" I.D. and fittings must have the same inside dimensions.
4.1.6.
Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain that all connections are secure.
© Jack Sealey Limited
AIR NEEDLE SCALER/FLUX CHIPPER
MODEL NO:
Wear protective
Wear protective
clothing
gloves
Original Language Version
SA52
Wear ear
Wear a mask
protection
SA52 Issue 3 (H,F) 24/01/20

Advertisement

loading

Summary of Contents for Sealey SA52

  • Page 1 SA52 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 To replace the needles (16), unscrew the needle tube (19) from the barrel sleeve (12). Remove the needle holder (17) and replace the needles (16). (Use genuine Sealey needles only.) Refit the needle holder (17) into the needle tube (19), screw it onto the barrel sleeve (12) and tighten.
  • Page 3 Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...