254/279
Bosch Rexroth AG
Installation
12.5
MSK133 with terminal box type RLK1200, RLK1300
2
3
1
Power connection terminal box RLK1200 / RLK1300
2
Encoder connection plug-in connector RGS1001
3
Fan connection plug-in connector (provided, to be connected
on-site)
Fig. 12-1:
MSK133
①⑤
Screw connection
②
O-ring
③
Adapter plate for holding the screw connection, reduction, ex‐
tension
④
Reduction (optional for cable cross-sections 1.5, 2.5 mm²), ex‐
tension (optional for RLK1200 / 16 mm²)
⑥
Adapter plate mounting screws
⑦
Cover screws
⑧
Cover
⑨
Seal of terminal box cover
⑩
Mounting screws of terminal box (4 pieces)
Fig. 12-2:
Assembly RKL1200, RKL1300
DOK-MOTOR*-MSK********-PR12-EN-P
Synchronous Servomotors MSK