CAUTION
R32
REFRIGERANT
This AIR-TO-WATER HEATPUMP contains
and operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to National, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance and/or service of this product.
SAFETY PRECAUTIONS
Read the following "SAFETY PRECAUTIONS" carefully before installation.
Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the
model to be installed.
The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication
used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the seriousness is classifi ed by
the following indications.
WARNING
CAUTION
The items to be followed are classifi ed by the symbols:
Carry out test running to confi rm that no abnormality occurs after the installation. Then, explain to user the operation, care and
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
This appliance is not intended for accessibility by the general public.
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. Any unfi t method or
using incompatible material may cause product damage, burst and serious injury.
Do not install outdoor unit near handrail of veranda. When installing outdoor unit at veranda of high rise building, child may climb up to outdoor
unit and cross over the handrail and causing accident.
Do not use unspecifi ed cord, modifi ed cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other electrical
appliances. Poor contact, poor insulation or over current will cause electrical shock or fi re.
Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen.
ACXF60-37671-AC
This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties only.
Symbol with white background denotes item that is PROHIBITED.
Symbol with dark background denotes item that must be carried out.
Required tools for Installation Works
1
Phillips screw driver
2
Level gauge
3
Electric drill, hole core drill
(ø70 mm)
4
Hexagonal wrench (4 mm)
5
Spanner
6
Pipe cutter
7
Reamer
8
Knife
9
Gas leak detector
10
Measuring tape
Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING
CAUTION
CAUTION
CAUTION
WARNING
ENGLISH ................ 1
DANSK ................. 11
11
Thermometer
12
Megameter
13
Multimeter
14
Torque wrench
18 N•m (1.8 kgf•m)
42 N•m (4.3 kgf•m)
55 N•m (5.6 kgf•m)
65 N•m (6.6 kgf•m)
100 N•m (10.2 kgf•m)
15
Vacuum pump
16
Gauge manifold
This symbol shows that this equipment
uses a fl ammable refrigerant. If the
refrigerant is leaked, together with
an external ignition source, there is a
possibility of ignition.
This symbol shows that the Operation
Manual should be read carefully.
This symbol shows that a service
personnel should be handling this
equipment with reference to the
Installation Manual.
This symbol shows that there is
information included in the Operation
Manual and/or Installation Manual.
1

Advertisement

loading

Summary of Contents for Panasonic WH-UD03JE5 Series

  • Page 1 ENGLISH ....1 DANSK ....11 Installation Manual AIR-TO-WATER HEATPUMP OUTDOOR UNIT WH-UD03JE5*, WH-UD05JE5*, WH-UD07JE5*, WH-UD09JE5* Required tools for Installation Works CAUTION Phillips screw driver Thermometer Level gauge Megameter Electric drill, hole core drill Multimeter (ø70 mm) Torque wrench Hexagonal wrench (4 mm) 18 N•m (1.8 kgf•m) Spanner 42 N•m (4.3 kgf•m)
  • Page 2 Do not insert your fi ngers or other objects into the unit, high speed rotating fan may cause injury. Do not sit or step on the unit, you may fall down accidentally. Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and prevent breathing. When install or relocate outdoor unit, do not let any substance other than the specifi...
  • Page 3 Installation work. It may need two or more people to carry out the installation work. The weight of outdoor unit might cause injury if carried by one person. Keep any required ventilation openings clear of obstruction. PRECAUTION FOR USING R32 REFRIGERANT •...
  • Page 4 Servicing 2-1. Service personnel • Any qualifi ed person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certifi cate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specifi...
  • Page 5 Repairs to sealed components • During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. • If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
  • Page 6 Decommissioning • Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its details. • It is recommended good practice that all refrigerants are recovered safely. • Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of recovered refrigerant. •...
  • Page 7: Select The Best Location

    SELECT THE BEST LOCATION   If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the condenser is not obstructed.   Avoid installations in areas where the ambient temperature may drop below -20°C. ...
  • Page 8: Connecting The Piping

    DISPOSAL OF OUTDOOR UNIT DRAIN WATER • When a Drain elbow is used, please ensure to follow below: - the unit should be placed on a stand which is taller than 50 mm. - cover the ø20mm holes with Rubber cap (refer to illustration below).
  • Page 9 AIR PURGING METHOD IS PROHIBITED FOR R32 SYSTEM AIR TIGHTNESS TEST ON THE REFRIGERATING SYSTEM Do not purge the air with refrigerants but use a vacuum pump to vacuum the installation. There is no extra refrigerant in the outdoor unit for air purging. •...
  • Page 10: Connect The Cable To The Outdoor Unit

    CONNECT THE CABLE TO THE OUTDOOR UNIT (FOR DETAIL REFER TO WIRING DIAGRAM AT UNIT) 1. Remove the control board cover from the unit by loosening the screw. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed fl exible cable (see below table), type designation 60245 IEC 57 or heavier cable.
  • Page 11 Monteringsmanual LUFT/VAND VARMEPUMPE UNDENDØRSENHED WH-UD03JE5*, WH-UD05JE5*, WH-UD07JE5*, WH-UD09JE5* Nødvendigt værktøj til installationen FORSIGTIG 1 Batteriskruemaskine 11 Termometer 2 Vaterpas 12 Megameter 3 Boremaskine, 13 Multimeter Bor (ø70 mm) 14 Momentnøgle 4 Skruenøgle (4 mm) 18 N•m (1,8 kgf•m) 5 Gaffelnøgle 42 N•m (4,3 kgf•m) KØLEMIDDEL 55 N•m (5,6 kgf•m)
  • Page 12 Stik aldrig dine fi ngre eller andre objekter ind i enheden. Den hurtigt roterende vifte kan give kvæstelser. Undgå at sidde eller træde på enheden, da du kan falde ned. Hold plastikposen (emballagen) væk fra små børn, den kan komme i nærkontakt med næse og mund og forårsage kvælning. Ved installation eller fl...
  • Page 13 Installationsarbejde. Der kan være behov for to personer eller mere til at udføre installationsarbejdet. Udendørsenheden kan være for tung for at en person kan bære den uden at komme til skade. Sørg for, at alle nødvendige ventilationsåbninger ikke tildækkes. FORHOLDSREGLER FOR BRUG AF R32-KØLEMIDDEL •...
  • Page 14 Service 2-1. Servicepersonale • Enhver kvalifi ceret person, der er involveret i at arbejde på eller bryde ind i et kølemiddelkredsløb, skal have et aktuelt gyldigt certifi kat fra en industriakkrediteret vurderingsmyndighed, som bemyndiger deres kompetence til at håndtere kølemidler sikkert i overensstemmelse med en industrianerkendt vurderingsspecifi...
  • Page 15 Reparationer på forseglede komponenter • Under reparation af forseglede komponenter skal alle elektriske forsyninger kobles fra udstyret, der arbejdede på, forud for enhver fjernelse af forseglede dæksler, osv. • Hvis det er absolut nødvendigt at have en elektrisk forsyning til udstyr under service, så skal der placeres en permanent driftsform for lækagesøgning på...
  • Page 16 Nedlukning • Før udførelse af denne procedure, er det vigtigt, at teknikeren er helt fortrolig med udstyret og alle dets detaljer. • Det er anbefalet god praksis, at alle kølemidler genvindes sikkert. • Før opgaven udføres, skal der tages en olie- og kølemiddelprøve i tilfælde af, at analyse er påkrævet inden genbrug af genvundet kølemiddel. •...
  • Page 17 VÆLG DEN BEDSTE PLACERING   Hvis der opsættes en markise over enheden for at beskytte den mod direkte sollys og regn, så sørg for at den ikke er vejen for kondensatorens varmeudstråling.   Undgå installationer i områder, hvor omgivelsestemperaturen er under -20 °C. ...
  • Page 18 BORTSKAFFELSE AF UDENDØRSENHEDENS VANDDRÆN • Når der bruges en Afl øbsstuds 1 , skal det sikres at: - enheden placeres på et stativ, som er højere end 50 mm. - dæk hullerne på ø20mm med gummikappe 2 (se illustrationen nedenfor). - brug en bakke (anskaffes af kunden), når det er nødvendigt at afhænde udendørsenhedens drænvand.
  • Page 19 LUFTRENSNINGSMETODE ER FORBUDT FOR R32-SYSTEM LUFTTRYKSTEST PÅ KØLESYSTEMET Rens ikke luften med kølemidler, men brug en vakuumpumpe til at vakuumere installationen. Der er ingen ekstra kølemiddel i udendørsenheden til luftrensning. • Inden systemet fyldes med kølemiddel, og før kølesystemet sættes i drift, skal nedenstående testprocedurer og acceptkriterier bekræftes af en certifi...
  • Page 20 TILSLUTNING AF KABLET TIL DEN UDENDØRS ENHED (FOR AT SE DETALJER SÅ REFERER TIL LEDNINGSDIAGRAMMET PÅ ENHEDEN) 1. Fjern styreprint dæksel fra enheden ved at løsne skruen. 2. Forbindelseskablet mellem den indendørs og udendørs enhed skal være lavet af godkendt polychloroprene-beklædt fl eksibel kabel (se tabellen nedenfor) af type 60245 IEC 57 eller stærkere kabel.
  • Page 21 Memo...
  • Page 22 Memo...
  • Page 23 Memo...
  • Page 24 Printed in the Czech Republic ACXF60-37671-AC...

This manual is also suitable for:

Wh-ud05je5 seriesWh-ud07je5 seriesWh-ud09je5 series