Frigidaire FFU11FK2AW2 Service Data Sheet

Automatic defrost upright freezer
Hide thumbs Also See for FFU11FK2AW2:

Advertisement

ELECTRICAL CIRCUIT
Power
Blk
See Diagram
Timer
Yel
Compressor
Blu
Cold
Control
Or
Defrost
Thermostat
EC33
SYSTEM SCHEMATIC
Condenser
High Side
Process
Drier
Tube
Capillary
Low Side Process Tube
SS8
IMPORTANT
If any green grounding
Wh
wires are removed dur-
ing
servicing,
must be returned to
their original position
and properly secured.
Fan
Defrost
WIRING DIAGRAM
Heater
Run
Capacitor
Compressor
Controller
Evaporator Coil
Suction
Tube
Compressor
Discharge
IMPORTANT SAFETY NOTICE
The information provided herein is
designed to assist qualified repair
personnel only. Untrained persons
they
should not attempt to make
repairs due to the possibility of
electrical
shock.
power cord before servicing.
INSTALLATION
This product is designed for "free standing installation only" and three inches
of clearance must be provided on all sides of the freezer for air circulation.
The freezer should be positioned on a solid floor, and the front of the
cabinet should be raised just enough to provide easy door closure when
open about half way.
Yel
REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.
Wh
TEMPERATURE CONTROL
6.2°F cut in, -5.7°F cut-out @ number 1 setting.
C10
DEFROST CONTROL
An automatic 30 minute defrosting period is initiated after every 12 hours of
compressor running time. During the defrosting period a thermostat will
switch the defrost heater off after the frost on the evaporator has melted. The
defrost thermostat closes at 10°F and opens at 50°F.
PERFORMANCE (Control at number 1 setting)
Room Ambient
Freezer Compartment Temperature
Percent Running Time
*Wattage Range (Last
Suction Pressure (Cut-in, cut-out), PSIG
High Side Pressure (Last
Specifications subject to change without notice.
*For complete performance data by model refer to service manual.
216803500
SERVICE DATA SHEET
AUTOMATIC DEFROST
UPRIGHT FREEZER
Disconnect
70°F
5 to 12°F
30-40%
of cycle)
110-125
1
3
14-0
1
of cycle), PSIG
110-125
3
90°F
5 to 12°F
45-55%
115-130
14-0
150-165
PD645

Advertisement

loading

Summary of Contents for Frigidaire FFU11FK2AW2

  • Page 1 This product is designed for “free standing installation only” and three inches of clearance must be provided on all sides of the freezer for air circulation. The freezer should be positioned on a solid floor, and the front of the...
  • Page 2 CIRCUIT ÉLECTRIQUE Courant électrique Noir Blanc Voir schéma Minuteur Jaune Compresseur Bleu Commande de froid Ventilateur Orange Chauffage Thermostat de dégivrage de dégivrage Condensateur Contrôleur du compresseur FEC33 SCHÉMA DU SYSTÈME Condenseur Serpentin d'evaporation Tube de Conduite traitement d'aspiration Déshydrateur côté...