Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND
CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE, AND/OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY.
1.
SAFETY INSTRUCTIONS
1.1.
ELECTRICAL SAFETY ML60gP LEADLAMP 60W/230V
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other
connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A
Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current
Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by
an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
1.1.1. The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.
and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check
all connections to ensure that none are loose.
1.1.6. Important: Ensure that the voltage marked on the appliance matches the power
supply to be used and that the plug is fitted with the correct fuse - see fuse rating
at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors. Immediately have
any faulty item repaired or replaced by a qualified electrician. When a BS 1363/A
UK 3 pin plug is damaged, cut the cable just above the plug and dispose of
the plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends
beyond the cable restraint and that the restraint is tight.
Double insulated products, which are always marked with this symbol
rewire, connect the wires as indicated above - DO NOT connect either wire to the earth terminal.
1.1.10. Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure
that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket
with your electrician.
1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance
plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use
of 2.5mm² section cable.
1.2.
ELECTRICAL SAFETY ML6012gP LEADLAMP 60W/12V
WARNING! Disconnect lamp from the power source before changing bulbs, servicing or performing any maintenance.
1.2.1
Ensure the voltage of the power source is suitable for the lamp.
1.2.2. The lamp has dual connection feature for use in cigarette lighter socket or connection to a battery, isolate the connectors that are not
in use to avoid shorting, as follows: If connected to lighter socket isolate clamps by placing each battery clamp in separate holster
supplied, if connected to battery isolate cigarette plug by placing in supplied holster.
1.2.3. To avoid short-circuit and possible flesh burns, remove personal metallic items such as rings, bracelets, necklaces and watches before
connecting the lamp to a battery.
1.2.4. Connect lamp power lead to battery with the RED clamp (+) positive to the battery positive terminal, and BLACK clamp (-) negative to
negative terminal.
1.2.5. If the connecting battery terminals are corroded or dirty, clean them before attaching the lamp clamps in order to achieve good contact.
WARNING! DO NOT attempt to connect a 12 Volt lamp to any mains power supply.
1.2.6. DO NOT cross connect the power leads when connecting to a battery.
1.2.7. DO NOT pull the power cables or clamps from the battery terminals. Remove by pressing the clamp release spring.
1.2.8. DO NOT touch the bulb when operating, allow to cool before servicing.
1.3.
GENERAL SAFETY
WARNING! Disconnect lamp from mains power before changing bulb or performing any maintenance.
Replace or repair damaged parts. Use genuine Sealey parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
Maintain the lamp in good condition.
DO NOT use the lamp if damaged.
DO NOT use lamp close to paint fumes, solvents or other flammable liquids or flammable waste, such as wipes or cleaning rags.
DO NOT fit a bulb larger than 60 watts.
When not in use switch off the lamp and disconnect from power supply.
INSTRUCTIONS FOR:
LEAD LAMPS WITH GRIPPER
MODEL No:
, are fitted with live (brown) and neutral (blue) wires only. To
Original Language Version
ML60GP, ML6012GP
Yellow & green
Earth Wire
Blue
Neutral
Wire
FUSE RATING 3 AMP
ML60GP, ML6012GP
Brown
Live
Wire
Cable
Restraint
Issue: 2 - 12/01/10

Advertisement

loading

Summary of Contents for Sealey ML60GP

  • Page 1 ML60GP, ML6012GP MODEL No: Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS.
  • Page 2 (Always use the correctly rated bulb). 4.1.3. GENERAL Clean the lamp with a dry, dust-free cloth. DO NOT use solvents, or abrasives to clean the lamp. ML60GP Spare bulb Part No: ML60GP/B 60W CLEAR BULB. ML6012GP Spare bulb Part No: BS60 60W PEARL BULB. Fig.2.

This manual is also suitable for:

Ml6012gp