Cooking process

 For example, you switch on a cooking
zone at the highest power level to
heat a pan for frying. You reduce the
power level after approx. 10 seconds
to 4 minutes (60 seconds to
5 minutes for a for a HiLight hob).
The cooker hood recognises a cooking
process.
The cooker hood switches itself on and
when the hob power level has been
reduced, the hood switches to fan
power level 3 and remains at that level
for approx. 5 minutes.
After that, the cooker hood power level
is determined automatically by the
Con@ctivity function.
You can select another power level
manually before then.
Switching off
 Switch off all cooking zones.
The power level is gradually reduced
until the fan finally switches off.
This helps to neutralise any lingering
vapours and odours in the air.
Depending on the last active fan level,
the process takes 2 to 5 minutes.
30 seconds after the fan is switched off,
the hob lighting switches off.
1 minute later, the deflector plate
retracts.
The cooking process is then finished.
Operation (Automatic mode)
Leaving automatic mode
temporarily
To leave automatic mode temporarily
during cooking:
 Manually select a different fan power
level, or
 Manually switch the cooker hood off,
or
 Activate the run-on function  on
the cooker hood. The fan will switch
itself off after the selected run-on
time, and the lighting will remain on.
The cooker hood functions are now
operated manually (see "Operation
(Manual mode)").
If you switch off the fan manually in
Plug&Play mode, it continues to run at
level 1 (see "Operation (Manual
mode)" – "Switching off the fan").

Returning to automatic mode

The cooker hood will resume automatic
mode:
- If the cooker hood has not been used
for approx. 5 minutes after selecting
a fan power level manually, or
- If the manually selected fan power
level corresponds to the automatic
one again, or
- The cooker hood fan and the hob
have been switched off for at least
30 seconds.
Automatic mode will resume next
time the hob is switched on.