5. Remove the crimped receptacle contact spring from the tool and inspect the
connection. Make certain that the wire is flush with the crimped barrel and that
there are no loose strands of wire.
2.5. Relay Insertion
Orient the relay to the mounting base with the name plate right side up; then plug the
relay into the base. The relay should be pushed firmly against the mounting base while
depressing the latch rod. After the relay is completely seated in the base, release the
latch rod, and pull on the handle to ensure that the relay has locked in place.
Copyright 2019
SM 4574F, Rev. 4, March 2019
PV-250 Track Relay