LC-60/70/80LE650U/LE657U/C6500U/LE757U/LE857U,60/70LE755U/C7500U
10. Key writing
10.1. EDID writing (Main PWB: QPWBXF953WJN1)
1. Write the MAC key data on IC3104 mounted on the main PWB.
2. Carry out thorough data management to avoid redundant writing of data.
If the IC where data is written is damaged, replace the PWB since only the IC cannot be changed.
LC-80LE650U/LE657U/C6500U
Adjustment point
Adjustment conditions
1
HDMI EDID writing
Process mode
Analog RGB EDID
Model discrimination check
writing
(Main PWB)
10.2. MAC key writing (MAIN PWB: QPWBXF953WJN1)
1. Write the NETFLIX/WMDRM key data on IC3103 mounted on the main PWB.
2. Carry out thorough data management to avoid redundant writing of data.
If the IC where data is written is damaged, replace the PWB since only the IC cannot be changed.
10.3. NETFLIX/WMDRM key writing (MAIN PWB: QPWBXF953WJN1)
1. Write the wide vine key data on IC3103 mounted on the main PWB.
2. Carry out thorough data management to avoid redundant writing of data.
If the IC where data is written is damaged, replace the PWB since only the IC cannot be changed.
NOTE: For EDID of the analog RGB (DSUB 15pin), write the data on the process menu just like HDMI.
11. Factory setting
After completing the factory setting, pull out the AC cord to complete the setting.
CAUTION: Do not turn on the power after completing the factory setting. If the power is turned on, configure the factory setting again.
Adjustment point
Adjustment conditions
1
Factory setting
Complete the setting by
pulling out the AC cord.
Adjustment procedure
1. Enter the process mode.
2. Point the cursor to [HDMI EDID WRITE] and press the [ENT] key.
The writing is complete when [OK] is displayed.
(Both HDMI and analog RGB are written.)
[Caution]
Perform the data wriring after setting the model discrimination.
The data based on the model discrimination information is recorded in EEPROM.
Point the cursor to [INDUSTRY INIT (+Cause)], set to "ON" using [+]/[-] of the [VOL]
key, and press the [ENT] key.
The version confirmation screen appears on the green screen. It is completed when
[SUCCESS] is displayed at the top.
(If error occurs, [ERROR] is displayed on the red screen.)
Turn off the AC power.
The following items are initialized when configuring the factory setting.
1) User set value
2) Channel data (broadcasting frequency, etc.)
3) Password setting value
4) Operating time
5) Standby Cause
6) Auto installation flag