Note
The priority order of the mask display is in the sequence from A
(highest) to X (lowest).
When you set the parameters of masks non-sequentially, it is
recommended that you set the mask whose priority order is higher,
first.
pp pp pp pp: Mask bit
pp
bit
7 6 5
4
3
2
Mask
-
- X W V U T S -
pp
bit
7 6 5
4
3
2
Mask
-
- L
K
J
I H G -
The "-" must be "0".
qq, rr: Color code
Mask (color)
Code (qq, rr)
Black
00 h
Gray1
01 h
Gray2
02 h
Gray3
03 h
Gray4
04 h
Gray5
05 h
Gray6
06 h
White
07 h
Red
08 h
Green
09 h
Blue
0A h
Cyan
0B h
Yellow
0C h
Magenta
0D h
Mosaic
Setting pan/tilt angle
Angle/Parameter of Angle (ppp, qqq)
-180
-90
800h
C00h
Set the angle resolution to 360 (degree)/4096 (1000h).
pp
1 0 7 6 5
4 3 2 1 0
- R Q P O N M
pp
1 0 7 6 5
4 3 2 1 0
-
F E D C B A
Translucence (qq, rr)
10 h
11 h
12 h
13 h
14 h
15 h
16 h
17 h
18 h
19 h
1A h
1B h
1C h
1D h
7F h
0
90
180
400h
800h
Motion Detection (MD) Function
This function instructs the camera to detect movement
within the monitoring area and then send an alarm
signal automatically.
The Detect signal goes out through the VISCA
Command.
Features
• You can set a frame for the detection range of
16 (horizontally) × 8 (vertically) blocks.
• You can set up to four frames.
• When the motion is detected in the set frame, the
Alarm Replay VISCA Command is sent.
• The threshold level for detection can be set (common
to four frames).
• The interval of alarm detection can be set up to
255 seconds in units of one second.
• You can set on/off for each frame.
• The frame number is also sent with Alarm Replay to
report in which frame the motion has been detected.
Frames
Setting frames
You can set the frame by assigning the starting point
and terminating point vertically and horizontally. You
can set up to four frames.
When motion is detected within the range where
frames overlap
The alarms are sent for both frames.
Frame 1
Frame 2
At this position, the
Frame 3
alarm for frame 3 is
sent.
Frame 4
1
Basic Functions
Within this overlapped
range, alarms are sent for
both frame 3 and frame 4.