LG LTCS20020 Series Service Manual page 42

Hide thumbs Also See for LTCS20020 Series:
Table of Contents

Advertisement

8) Over cooling in Refrigerator room
No
1.- Unplug connector from CON8.
1
2.- Check resistance in wires White to
White.
The sensor is determined by
the temperature.
For example, 30
2
Reset the unit and
Input Test 1 Mode.
(push the button 1 time)
3
Open the refrigerator door and
Check the air flow.
4
Input Test 2 Mode and
Check the air flow.
(push the button 1 time)
Checking flow
indicates 32°F.
Result & SVC Action
Temperature
23°F
°C
32°F
°C
41°F
°C
50°F
°C
59°F
°C
Status
Windy
No windy
Status
Windy
No windy
42
Copyright © 2020 LG Electronics Inc.All right s reserved.
Only training and service purposes.
Result
38
30
24
19.5
16
SVC Action
Go to the 4
Check the PCB
SVC Action
Change the PCB
It 's normal

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ltcs20020bLtcs20020s

Table of Contents