5.11

Noise level

Noise emitted during operating the lift should be
less than 70dB. For your health consideration, it is
suggested to place a noise detector in your working
area.
5.12

Construction of the lift

This model is specially designed for lifting motor
vehicles. It is electro-hydraulic powered and mainly
composed by two lifting platforms and two auxiliary
lifts and a set of power unit. The gear pump works
when power supply is connected and meanwhile oil in
the pump will push upwards the pistons of oil cylinders.
Thus, scissor arms of the lift rise accordingly.
Fig. 1:
Construction
1 Base plate assembly
2 Arm of the lifting platform
3 Cylinder of the lifting platform
4 Lifting platform
5 Cylinder of auxiliary lift
6 Arm of auxiliary lift
7 Lifting platform of auxiliary lift
5.13

Dimension

Fig. 2:
Dimension(Unit: mm)
Robert Bosch GmbH
Product Description | VLS 5235 | 11
5.14

Safety devices descriptions

Fig. 3:
Safety devices
No. Safety device
Function
1
Lowering limit
The lifting platforms will automatically
switch of lifting
stop lowering at 500mm height above
platform
the ground. It needs to push DOWN II
button to continue the lowering move-
ment, meanwhile alarming buzzer will
be heard warning service persons be-
ing away from the moving parts.
2
Raising limit
Make the lifting platform stop rais-
switch for lifting
ing when reach a height of 1850mm
platform
above the ground.
3
Raising limit
Make the auxiliary lift stop rising
switch for the aux-
when reaches a height of 450mm
iliary lift
above lifting platform.
4
Tip-up protection
Protect lifting platform from tipping-
of lifting platforms
up, in case load on it is not evenly dis-
tributed.
5
Tip-up protection
Protect auxiliary lift from tipping-up,
of the auxiliary lift
in case load on it is not evenly distrib-
uted.
6
Mechanical lock
Protect the lifting platform from fall-
for lifting platform
ing down in case oil cylinders loss
forces caused by break down of hy-
draulic system.
7
Mechanical lock
Protect the auxiliary lift from falling
for the auxilia-
down in case oil cylinders loss forc-
ry lift
es caused by break down of hydrau-
lic system.
8
Wheel retainer
Protect wheels of vehicle from rolling
off the platform.
9
Laser protection
Protect vehicle from rollover by stop-
unit
ping lowering or rising movement in
case the two platforms are not syn-
chronized.
10
Anti-surge valve
Slow down the falling speed of lifting
platform in case there is leakage of
hydraulic oil hoses.
11
24V operation
Safety voltage for operators.
voltage