Please check the following before commencing startup.
Power must be supplied to the monobloc unit for at least 8 hours before start up in or-
•
der to provide sufficient power to the compressor heater
Check all electrical wiring and connections
•
Make sure all auto air vents are open and the pressure relief valves are closed
•
Make sure the system is filled with the correct coolant fluid to around 2 Bar
•
Check the expansion vessel is large enough. The Yutaki M unit contains a 6 litre expan-
•
sion tank large enough for 150 litres. For larger water volumes or more than 8m
height difference then an extra expansion vessel is required.
Check all fuses and circuit breakers.
•
Once you have selected Configuration Assistant Answer the questions -
Is this device attached to the
•
Is this device controlling the
•
Is this device used as the room thermostat of a
•
How many circuits do you
•
What are the heat emitters installed on circuit
•
Do you have a domestic hot water tank
•
Do you have a swimming pool
•
Do you have a boiler
•
Do you have an electric backup heater
•
How many thermostats are
•
As soon as you are set up as above enter Installer mode by pressing OK & Return
for 3 seconds and then entering the password right, down, left, right, enter.
The spanner icon should appear on the display. You are now ready for setup
T: 0191 516 6554
Pre-Start Checks
Controller Setup on Start Up
unit—YES
unit—YES
have—ONE
installed—NO
installed—NO
installed—NONE