Download Print this page
Whirlpool UI MISTRAL Manual
Whirlpool UI MISTRAL Manual

Whirlpool UI MISTRAL Manual

For i200 – i270

Advertisement

Quick Links

Induction hob
UI MISTRAL for I200 – I270
Golden Service Technical Training 2017
WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati
@WhirlpoolCorp #WhatMatters

Advertisement

loading

Summary of Contents for Whirlpool UI MISTRAL

  • Page 1 Induction hob UI MISTRAL for I200 – I270 Golden Service Technical Training 2017 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati @WhirlpoolCorp #WhatMatters...
  • Page 2 Induction UI Mistral for I200 and I270 UI Mistral I270 I200 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 3 Induction UI Mistral for I200 and I270 Chapter List Installation UI Mistral Operation Components Repair guide line Troubleshooting Marketing information WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 4 Installation Dimensions 65 cm Dimensions 77 cm Standard Installation Full integrated installation Electrical connection WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 5 Max. 492 m m R = Min. 6.5 m m Max. 8 m m Worktop thickness min. 30mm Idem for 650 mm WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 6 R = Min. 6.5 m m Max. 492 m m Max. 8 m m Worktop thickness min. 30mm Idem for 650 mm WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 7 Min. 480 m m R = Min. 6.5 m m Max. 492 m m Max. 8 m m Worktop thickness min. 30mm WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 8 Installation Standard Installation Distance “X” is specified in the hood’s documentation WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 9 100mm min.5mm min. 45mm min. 20mm min. 550mm min. 20mm 60mm 60mm min. 20mm min.5mm min. 45mm min. 550mm min. 20mm WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 10 Installation Standard Installation 90°C WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 11 Installation Standard Installation WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 12 Length Width DIM. 513/(480 590 Vetroceramic Cooktops Flush Installation 593/560 -492) -0/+2 513/(480 770 Vetroceramic Cooktops Flush Installation 773/750 -492) -0/+2 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 13 On the back side there are 2 hooks, no screws WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 14 N1 and N2 are not clamped together You have to clamp in order to allow using the cooktop with 1 phase 230V. WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 15 If the cooktop will be connected with 2 phase, the life connection (L1, L2) have to be cutted and connected one by one. WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 16 220-240V3 230V 2 Phase 2N 380-415V 3 N ~ AU-UK-IRL 380-415V 2 N ~ 220-240V R=black, S=brown, T=blue (gray), =E=yellow, N=blue WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 17 Exploded view User Interface Mistral Overview components Cooling fan Overview converter board ESAM connection Overview cable connection Induction coil power level WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 18 Touch control Mistral Filter Board Filter Board Connection cable IPC - UI IPC power board Plastic Housing I200 incluse Housing and Fan WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 19 Touch control Mistral Filter Board Cable Plastic Housing Fuse IPC power board Cover Electrical Connection cable IPC - UI connection IPC power board WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 20 Components Overview components Mistral I270 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 21 Components Overview components Mistral I270 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 22 Overview converter board Mistral I270 Input: = 230 Volts AC ± 10% Vmin = 207 VAC Vmax= 253 VAC fq = 50/60 Hz ± 2Hz WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 23 Overview converter board Mistral I270 Input: = 230 Volts AC (VAC) Vmin = 196VAC Vmax = 263 VAC fq = 50/60 Hz ± 2Hz WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 24 I200 converter board is prepared for ESAM usage via 7 pin connector. E-SAM cable has to be linked in pos. J34 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 25 Components Overview cable connections I270 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 26 Components Overview cable connections I200 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 27 Components Overview cable connections I200 (an example) WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 28 Components Overview cable connections Mistral i270 (Round coils, example) WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 29 Components Overview cable connections Mistral i270 (Round dual zone coil) WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 30 Components Overview cable connections Mistral i270 (Oval coils) WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 31 Double ring i270 260x260 Double ring i270 260x260 Double ring 260x260 i270 Double ring i270 260x260 Double ring i270 260x260 Double ring WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 32 OVI i270 (double) i270 OVI i270 (double) i270 OVI i270 (double) MOKA 2' i270 OVI i270 (double) i270 OVI i270 (double) WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 33 OVI i270 (single) i270 OVI i270 (single) i270 OVI i270 (single) i270 OVI i270 (single) i270 OVI i270 (single) i270 OVI i270 (single) WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 34 1850 i270 1650 i270 1450 i270 1300 i270 1200 i270 1050 i270 i270 i270 i270 i270 i270 i270 i270 i270 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 35 1850 i270 1650 i270 1450 i270 1300 i270 1200 i270 1050 i270 i270 i270 i270 i270 i270 i270 i270 i270 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 36 1200 i270 1100 i270 1000 i270 i270 i270 i270 i270 i270 i270 i270 i270 i270 i270 i270 i270 i270 i270 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 37 1300 i200 1200 i200 1100 i200 1000 i200 i200 i200 i200 i200 i200 i200 i200 i200 i200 i200 i200 i200 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 38 1700 i200 1550 i200 1400 i200 1200 i200 1000 i200 i200 i200 i200 i200 i200 i200 i200 i200 i200 i200 i200 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 39 1900 i200 1700 i200 1500 i200 1300 i200 1100 i200 i200 i200 i200 i200 i200 i200 i200 i200 i200 i200 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 40 OVI-5 (single) i200 OVI-5 (single) i200 OVI-5 (single) i200 OVI-5 (single) i200 OVI-5 (single) i200 OVI-5 (single) i200 OVI-5 (single) WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 41 OVI-3 (single) i200 OVI-3 (single) i200 OVI-3 (single) i200 OVI-3 (single) i200 OVI-3 (single) i200 OVI-3 (single) i200 OVI-3 (single) WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 42 Components NTC – components for I200 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 43 Components Zone – NTC for I200 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 44 Components NTC – components for I270 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 45 Components Zone NTC for I270 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 46 User Interface Mistral User Interface Touch sensors made through foils able to cover whole product range. Springs offer mechanical function only WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 47 The User Interface is supplied from the IPC board through its auxiliary, galvanically insulated, output. The ratings of this output are the following: Platform Voutput (Vdc) Imax (mA) Mistral 15,0 ± 5% WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 48 The Fan is driven with square wave in frequency and not in electric voltage. • The RPM value depend to the product state WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 49 The Fan is drived with square wave in frequency and not in electric voltage. • The RPM value depend to the product state WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 50 Touch control I270 Touch control I200 Cable IPC/UI I270 Cable IPC/UI I200 Fan I270 Fan I200 Converter board I270 Converter board I200 WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 51 Open the hob only from top! The back side of the frame is fixed with 2 hooks. WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 52 Open the hob only from top! Turn the glass frame in the front upwards. Push it backwards to unhook the clips at the back side. WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 53 Repair guide line Coils – disassembly Mistral I270 4 hooks WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 54 Repair guide line Coils – disassembly Mistral I270 Rotate the left coils in left side and the right coils in the right side WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 55 Repair guide line Coils – disassembly Mistral I270 Disconnect the coils pins Disconnect the NTC faston WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 56 Touch control – disassembly Mistral I270 Unclip the touch control from the support pins and disconnect the wiring to the IPCs. WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 57 Repair guide line Cable IPC/UI – disassembly - Mistral I270 Unplug the 2 connectors (IPC side – UI side) WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 58 Repair guide line Fan – disassembly Mistral I270 Remove the 2 fixing screws Unplug the cable from the IPC board WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 59 Repair guide line Converter board – disassembly Mistral I270 Disconnect the cable for IPC Remove the 4 fixing screws WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 60 Open the hob only from top! The back side of the frame is fixed with 2 hooks. WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 61 Turn the glass frame in the front upwards. Push it backwards to unhook the clips at the back side. WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 62 Repair guide line Coils – disassembly - Mistral I200 Remove the 4 screws WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 63 Coils – disassembly - Mistral I200 Rotate the left coils in left side and the right coils in the right side WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 64 Repair guide line Coils – disassembly - Mistral I200 Disconnect the coils pins Disconnect the NTC faston WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 65 Touch control – disassembly - Mistral I200 Unclip the touch control from the support pins and disconnect the wiring to the IPCs. WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 66 Repair guide line Cable IPC/UI – disassembly - Mistral I200 Unplug the 2 faston (IPC side – UI side) WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 67 Repair guide line Fan – disassembly - Mistral I200 Remove the 3 fixing screws Unplug the cable from the IPC board WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 68 Converter board - disassembly - Mistral I200 Disconnect the cable for IPC Remove the 2 fixing screws Disconnet the power cable. WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 69 Troubleshooting Demo Mode Configuration Mode Power Managment Failure code I200 and I270 Wiring Diagram WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 70 Once the demo mode is active the letters “dE” (“d” on the left side and “e” on the richt side) will appear and the mode is active. Follow same procedure (after unplugged the hob) to deactivate the Demo Mode WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 71 Within the first minute after the hob is plugged-in, execute the following key combo on the right timer indicated in the picture below: Press consequently (-), (+), (-), (+) button and then CL button WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 72 00 to 09 (10 conf. sets-up, always 0 on the left side) at this time Example shown for I200 Set configuration code WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 73 Through the (+) and (-) button of right timer is possible to scroll settings. To choice the preferred one it needs to press CL button to confirm WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 74 Change the IPC 400V Wrong Connection Verify connection of the product the mains. Change the IPC WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 75 If replacing the Coil with a new one did not fix the appliance, then the old coil is still good. Put it back in the appliance. Change the IPC WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 76 Verify connection of the coil NTC to the IPC, plug the cooktop, execute manual configuration ; COOKTOP EEPROM Configuration Error Change the IPC, execute manual configuration; WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 77 60730 Micro Program Flow Error 60730 Micro Watchdog Error BURNER Coil 1/2 NTC Stuck Change the coil tray; Change the IPC; WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 78 Check the Cooktop installation Check if the customer is using wrong diameter size pan/pot Change the Coil Tray; WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 79 If replacing the fan with a new one did not fix the appliance, then the old fan is still good. Put it back in the appliance. Change the IPC showing the failure. WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 80 F-42 DC link over voltage Type 2 1) Measure the mains voltage, if it is correct then: Replace the related IPC WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 81 Type 3 1) Configure the USIF. If this does not fix the appliance then: configuration. Replace the USIF with a new one WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 82 The memory is damaged. F-63 Not correct communication Type 2 erify connection/wiring between USIF/IPC (2 wires) USIF/IPC 2) replace USIF 3) replace IPC WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 83 Check the cooktop installation and cool down the appliance over-temperature C-82 Coil Over Temperature Type 1 1) Check the cooktop installation and cool down the appliance WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 84 Trouble Shooting Wiring Diagram Mistral I270 (example) WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 85 Trouble Shooting Wiring Diagram Mistral I200 (example) WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 86 Marketing information Product Architecture Mistral I 200 and I270 Legenda Safety Points WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 87 Marketing Mistral I 200 Product Architecture Oviform Coils Round Coils WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 88 Marketing Mistral I 270 Product Architecture WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 89 Marketing Legenda TBC = To Be Confirmed WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...
  • Page 90 VENTILATION - The hob protects the furniture by ventilated system AUTO-OFF SYSTEM - The power is off if the using time is too long WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati...