Page 1
AJ8 SWITCHES WITH TRIP Power Rocker Switches with an Electromagnetic FUNCTION UPGRADED TYPE Reset Function FEATURES • CT terminal adopted for coil terminal • Long electrical life • Assures excellent ability to withstand inrush current when used to turn a power supply on/off.
AJ8 Switches with Trip Function Upgraded Type ■ With indication on actuator 1) With indication (Actuator color: Dark gray) Part No. Poles Operation type Coil voltage Flange color: Dark gray Flange color: Black 5V DC AJ8R1011ZCF AJ8R1011ZBCF Single throw (ON-OFF)
Page 3
AJ8 Switches with Trip Function Upgraded Type ■ Characteristics Item Specifications Manual operation Min.10 (at 7 cpm.,at rated load) Electrical life Coil operation Min.10 (at 7 cpm.,at rated load), Min.5×10 (at 7 cpm. 5A 125V AC) Mechanical life Min.5×10 (at 20 cpm.) Contact resistance Initial, Max.
AJ8 Switches with Trip Function Upgraded Type OPERATING PRINCIPLE • Manual operation is a repetition of (A) and (B). This operation is independent of the electromagnetic reset function. • The reset mechanism operates only when an electromagnetic reset has occurred. (C)
Page 5
AJ8 Switches with Trip Function Upgraded Type CONNECTION OF COIL TERMINALS ■ Cable with connector Min. order unit: 1 bag (set of 10) AJ8C0001 Outer carton: contains 20 bags (total of 200 sets) CT connector • TE Connectivity Ltd.’s Crimping type...
Technical Terminology & Cautions for Use Technical Terminology & Cautions for Use (Operation Switches) TECHNICAL TERMINOLOGY ■ Rated values ■ Shock resistance Values indicating the characteristics and performance guarantee Max. shock value where a closed contact does not open for standards of the switches.
Page 7
Technical Terminology & Cautions for Use TYPES OF LOAD ■ Resistance load ■ Motor load Resistance load is a power factor of 1 (cos φ = 1) where the load Contacts may adhere due to the starting current at the start of is only for the resistance portion.
Page 8
Technical Terminology & Cautions for Use CAUTIONS FOR USE ■ Environment of use ■ Wiring 1) Please consult us when using under the following conditions: 1) When using a PC board terminal switch as soldering • Environments where hydrogen sulfide or other corrosive gases terminals, use thin lead wires and be sure to wind them on the are present.