4-1. Main Specifications

Measurement distance
(WD:Working Distance)
Measurement range
Measutement speed range
Maximum acceleration
of target measurement object
Measurement resolution
Measurement
accuracy ※1
Measurement repeatability ※2
Light source
Sampling rate
Pulse output
Other
input/output
USB interface
Operating temperature
Storage temperature
Humidity
Vibration
Protection class ※3
Power voltage
Power consumption
Weight
Dimensions
Materials
Cable length
※1 When measured in our environment.
※2 When measured in our conditions.
※3 When used the optional kit.
※4 A glossy surface similer to a mirror may not be measured.
Non-Contact Displacement Sensor User's Manual Rev 1.00
WD:70mm±5mm
WD:70mm±15mm
Trigger input
Error output
Power cable
I/O cable
USB cable
70mm
±15mm
-4,000mm/s to 4,000mm/s
(Including the stop state)
100G
1μm
±0.2% or 100μm
±0.5% or 100μm
0.02% or 20μm
LED
4kHz
1μm to 1,000μm (Set on application software)
Phase A/B (RS422-compliant line driver)
Photocoupler insulation:5 to 24V
Open collector output
(Photocoupler insulation):5 to 24V
USB 2.0 Full Speed
(Compatible with USB 1.1) compliant
0℃ to 50℃
-30℃ to 60℃
80%RH or lower
Bare vibration:Evaluated in vibrating
environment
Frequency:10 to 500Hz 5G sin wave 2 hours for
XYZ directions
IP65
DC12V to 24V
8W
1.2kg
156x127x67
Aluminum, Window(Stainproof coating)
5m
5m
5m