TROUBLESHOOTING & WARRANTY
Troubleshoot your problem by using the chart below. If the air purifier still does not
work properly, contact BLACK+DECKER customer service center or the nearest
authorized service center.
WARNING: Users must never troubleshoot internal components.
TROUBLE
Appliance does not turn on
The fan does not work
The air purifier beeps
The air purification is poor
Air purifier is noisy
The REPLACE FILTER
light is still illuminated after
replacing the filter
Air quality indicator is
always red (Model BAPT02
only)
SPECIFICATIONS
Voltage: DC 24V
Unit Dimensions (W x D x H): 8.9" x 8.9" x 12.2"
Net Weight: Approx. 3.3 lbs
Page 12
POSSIBLE CAUSE
Appliance is not plugged in
Something is obstructing the fan.
Packing material may not have
been removed
The filter needs to be replaced
The filter was not installed correctly
There is not enough clearance
around the air purifier
Air Purifier is set at a low speed
setting
The filter needs to be replaced
Something may be obstructing the
fan or an object may be inside the
air purifier
The plastic packaging may not have
been removed from the filter.
The filter was not installed correctly
or the filter was not reset by pressing
the REPLACE FILTER button
There is a source of pollution near
the air purifier such as someone
smoking.
The particle sensor may be clogged
with dust or other debris.
POSSIBLE REMEDY
Check that the AC Power Adapter is
properly connected to the air purifier and
that the adapter is plugged into a working
outlet
Make sure nothing is obstructing the fan and
all material has been removed from the unit
and the filter.
Replace filter
Make sure the filter was installed properly
with the plastic bag removed. After installing
the filter press the REPLACE FILTER
indicator light for 3 seconds
Make sure nothing is obstructing the airflow
around the air purifier.
Set at a higher speed setting
Replace filter
Remove any foreign object from the air
purifier
Make sure the filter was installed on a firm
level surface with the plastic bag removed
Make sure the filter was installed properly
with the plastic bag removed. After installing
the filter press the REPLACE FILTER
indicator light for 3 seconds
After operating the air purifier for a period
of time, the air quality indicator will
turn blue or green when the air quality is
getting better.
Wipe the particle sensor and make sure
there is no dust or debris obstructing it.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bapt02

Table of Contents