Advertisement

SPLIT TYPE WALL MOUNTED
INVERTER AIR CONDITIONER
USER ' S MANUAL AND
INSTALLATION MANUAL
MODELS:
SIA90IN/SIA90CO
SIA120IN/SIA120CO
SIA180IN/SIA180CO
SIA240IN/SIA240CO

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool SIA90IN

  • Page 1 SPLIT TYPE WALL MOUNTED INVERTER AIR CONDITIONER USER ' S MANUAL AND INSTALLATION MANUAL MODELS: SIA90IN/SIA90CO SIA120IN/SIA120CO SIA180IN/SIA180CO SIA240IN/SIA240CO...
  • Page 2: Before Using The Appliance

    BEFORE USING THE APPLIANCE To make the most out of your new appliance, please read the user instructions carefully and keep them handy for future consultation. SAFETY PRECAUTIONS • The Installation and service/repair must be • Never block the air inlet or outlet of indoor and performed by a qualified technician, in outdoor unit.
  • Page 3: Product Description

    PRODUCT DESCRIPTION Indoor unit Outdoor unit 1. Air Intake 11. Air Intake 2. Front Panel 12. Pipes and Power Connection Cord Display panel 13. Drain Hose 4. Air Outlet Note: Condensate water drains at COOLING 5. Electrical box or DRY operation. 6.
  • Page 4 CONTROL PANEL DISPLAY INDICATORS DESCRIPTION Temperature indicator (1) Displays set temperature and room temperature. Default temperature showing is room temperature. It shows set temperature under the settings by using remote controller, then back to show room temperature after a few seconds. Operating mode indicator (2) Display blue lignt under COOL or DRY operation.
  • Page 5: Before Using The Remote Control

    BEFORE USING THE REMOTE CONTROL How to insert the batteries 1. Use your thumb to press the cover and gently slide it down as shown. 2. Hold the two sides of the cover and press to let the cover deform a little bit, at the same time, press down the caudal of cover as shown to open it.
  • Page 6: Remote Control Functions

    REMOTE CONTROL FUNCTIONS 1. POWER BUTTON Starts or stops the appliance by pressing this button. 2. COOL BUTTON Used to start the cooling operation. 3. FAN SPEED BUTTON Used to select fan speed in sequence auto, silent, low, medium or high. 4-5.
  • Page 7 REMOTE CONTROL INDICATORS Auto fan speed indicator Signal transimission indicator Silent fan speed indicator 6th Sense operation indicator Low fan speed indicator Cooling operation indicator Mid fan speed indicator Dry operation indicator High fan speed indicator Fan operation indicator Timer on function indicator Sleep operation indicator Timer off function indicator Button lock indicator...
  • Page 8 ORDINARY USING GUIDE 1. Turning on Press button to activate the appliance. During mode changes wait a few seconds and repeat the operation if the unit does not respond at once. 2. Selecting mode Press the button to select the operation mode you want, such as 6the Sense, COOL, DRY, SLEEP, TURBO.
  • Page 9 MODE AND FUNCTION DESCRIPTIONS 6th SENSE MODE (1) Press the button, the unit enters 6th sense mode directly regardless of the appliance is on or off. Under this mode, operation mode, temperature and fan speed are automatically set based on the actual room temperature.
  • Page 10 CLOCK function Press this button to set the real time clock. 1. Press the CLOCK button for one time, the clock starts to flicker. 2. Press the HOUR button to set the hour of time. Time setting will be changed for 1 hour by each press. 3.
  • Page 11 RESET function LOCK function If remote controller shows error code or Press the button by using a pin to lock all the other can not be used, press this button by using buttons on remote controller. Press again to unlock it. a pin to let the remote control back to default settings.
  • Page 12: Maintenance

    MAINTENANCE Clean front panel of Indoor Unit 1. Disconnect from the power supply Turn off the appliance first before disconnecting from power supply. 2. Remove the front panel Open the front panel as shown by the arrow (Fig. A). Pull the slots at the side of the front panel with force to take out the front panel (Fig.
  • Page 13: Troubleshooting

    COOLING or DRY operation the outlet mode. Note: If the problems still have, turn off the appliance and disconnect from power supply, then contact the nearest Whirlpool Authorized Service Center. Do not attempt to move, repair, disassemble, or modify the appliance by yourself.
  • Page 14: Installation Instructions

    INSTALLATION INSTRUCTIONS Installation diagram Distance from ceiling should be over 150mm Distance from wall should be over 50mm Distance from the wall Indoor unit should be over 50mm Distance from floor should be over 2000mm Outdoor unit Air intake distance from the wall should be over Air intake distance from 250mm...
  • Page 15: Installation Service

    INSTALLATION SERVICE Before installation 4. Check the product to verify that it has not been 1. Please read this manual carefully before damaged before installation. installation. 5. Mount with the lowest moving parts of indoor 2. The appliance must be installed according to unit at least 2.0m above floor or grade Level.
  • Page 16 Select the best location Indoor unit Location for Installing Indoor Unit • Where there is no obstacle near the air outlet and air can be easily blown to every corner of room. Pipe length is • Where piping and wall hole can be easily 3~10 meters arranged.
  • Page 17: Indoor Unit Installation

    INDOOR UNIT INSTALLATION 1. Installing the Mounting Plate • Select a location to install the mounting plate according to the indoor unit location and piping direction. Tapping screw • Adjust the mounting plate horizontally with a gradienter or plumb line. •...
  • Page 18 IMPORTANT: Piping Joints Thermal Insulation: Wrap the piping joints with thermal insulating materials and then wrap with a vinyl tape. Wrapped with vinyl type Thermal insulation Thermal Insulation piping: a. Place the drain hose under the piping. b. Insulation material: polythene foam over 6mm in thickness. NOTE: Drain hose is prepared by user.
  • Page 19 4. Connecting the Cable • Indoor Unit Covering plate 1) Open the front panel, remove the covering plate by loosening the screw. 2) Connect the power connecting cord to the indoor Power Connection unit by connecting the wires to the terminals on the Cable control board individually as follows.
  • Page 20: Wiring Diagram

    WIRING DIAGRAM • 9K/12K Models • 18K/24K Models Outdoor unit Outdoor unit Indoor unit Indoor unit Terminal Terminal Terminal Terminal Power connecting cord Power connecting cord Black Black Black Yellow/Green Yellow/Green Black Blue Blue Blue Blue Brown Brown Brown Brown Yellow/Green Yellow/Green Note:...
  • Page 21: Air Purging

    AIR PURGING Air containing moisture remaining in the refrigeration cycle may cause a malfunction on the compressor. After connecting the indoor and outdoor units, evacuate air and moisture from refrigerant cycle using a vacuum pump, as shown below. Note: Because the system pressure is high and also to protect the environment, be sure not to discharge the refrigerant to the air directly.
  • Page 22: After Sales Service

    AFTER SALES SERVICE Before contacting the Customer Care Centre: If repair work has to be carried out, contact the Customer Care Centre (Use of original spare 1. Try to solve the problem yourself based on the parts and a proper repair is guarenteed). descriptions given in the "Troubleshooting".

Table of Contents