5. Specifications

Input power
Model name
(W)
LGH-50RVS-E
190
LGH-80RVS-E
325
LGH-100RVS-E
445
* The above values apply during Lossnay ventilation when the fan speed is set to Fan speed 4 at the rating pressure loss and 230 V / 50 Hz.
* For the specifications at the other frequency or voltages, contact your dealer.
* The values given in the table for the noise level reflect the levels measured at a position 1.5 meters directly under the unit in an anechoic
chamber.
* Noise change or increase may occur because of the Bypass-Automatic function or Automatic fan speed change by timer setting and/or other
functions.
* Temperature Exchange efficiency (%) are based on winter condition.
* Mitsubishi Electric measures products according to ISO 16494:2014, therefore P-Q curves are measured by chamber method.
* On-site commissioning measurements by pitot tube method could be as much 20% different from ISO test room conditions. If the measuring
point is close to sources of turbulence like bends, contractions and dampers etc, it is difficult to measure air volume correctly. A straight duct
length more than 10D (D=duct diameter) from the source of turbulence is recommended for correct measurement. On-site measurement
should therefore be performed in accordance with BSRIA guideline (Commissioning Air System. Application procedures for buildings
AG3/89.3(2001))

6. After-sales servicing

Consult with your dealer about the after-sales services provided for
this Lossnay product.
■ Recommended inspection and maintenance
After several years of use, the following might occur. We recommend inspection and maintenance by a professional.
- Water leakage due to clogging of drain pipe
- Entry of dust due to deterioration of filters
- Abnormal noise or vibration due to the motor reaching the end of its service life
- Air leakage due to the Lossnay core reaching the end of its service life
The following are consumables:
- Motor
- Supply air filter
- Exhaust air filter
- Lossnay core
- Backflow stopper
- Circuit board
- Thermistor
■ Repair costs include technical fee, cost of parts, (and business trip charges), etc.
Inspect your unit of good service!
Attentive inspection
Have you
noticed?
Air volume
Static pressure
(Pa)
(m
/h) (L/S)
3
500
139
150
800
222
170
1000
278
190
● Fan do not run when the unit is turned on.
● Abnormal noises or vibrations while the unit is running
● Retarded or irregular rotations
(Motors are component which requires maintenance.)
● Burnt odor
● Corroded or damaged mounting parts or location
HEAD OFFICE:
TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Temperature exchange
Noise (dB)
efficiency (%)
1.5 m below the unit
87
82
82
If you hear strange sounds, if no air is blown out or if some other
trouble occurs, switch off the power and contact your dealer. Consult
with your dealer concerning the cost of inspection or repair work.
Eng-7
Weight
(kg)
33
55
36
63
37
73
Turn off the unit. Then,
contact your dealer for
Stop
prevention of failure or
running.
hazard. The dealer should
appraise the possible cost.